Influence of Connection Geometry and SVC-IVC Flow Rate Ratio on Flow Structures within the Total Cavopulmonary Connection: A Numerical Study
- 30 July 2002
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 124 (4) , 364-377
Abstract
The total cavopulmonary connection (TCPC) is a palliative cardiothoracic surgical procedure used in patients with one functioning ventricle that excludes the heart from the systemic venous to pulmonary artery pathway. Blood in the superior and inferior vena cavae (SVC, IVC) is diverted directly to the pulmonary arteries. Since only one ventricle is left in the circulation, minimizing pressure drop by optimizing connection geometry becomes crucial. Although there have been numerical and in–vitro studies documenting the effect of connection geometry on overall pressure drop, there is little published data examining the effect of SVC-IVC flow rate ratio on detailed fluid mechanical structures within the various connection geometries. We present here results from a numerical study of the TCPC connection, configured with various connections and SVC:IVC flow ratios. The role of major flow parameters: shear stress, secondary flow, recirculation regions, flow stagnation regions, and flow separation, was examined. Results show a complex interplay among connection geometry, flow rate ratio and the types and effects of the various flow parameters described above. Significant changes in flow structures affected local distribution of pressure, which in turn changed overall pressure drop. Likewise, changes in local flow structure also produced changes in maximum shear stress values; this may have consequences for platelet activation and thrombus formation in the clinical situation. This study sheds light on the local flow structures created by the various connections and flow configurations and as such, provides an additional step toward understanding the detailed fluid mechanical behavior of the more complex physiological configurations seen clinically.Keywords
This publication has 29 references indexed in Scilit:
- Bidirectional superior cavopulmonary anastomosis improves mechanical efficiency in dilated atriopulmonary connectionsThe Journal of Thoracic and Cardiovascular Surgery, 1999
- The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation modelJournal of Biomechanics, 1999
- Fluid dynamic comparison of intra-atrial and extracardiac total cavopulmonary connectionsThe Journal of Thoracic and Cardiovascular Surgery, 1999
- The nature of flow in the systemic venous pathway measured by magnetic resonance blood tagging in patients having the fontan operationThe Journal of Thoracic and Cardiovascular Surgery, 1997
- Application of Computational Fluid Dynamics Techniques to Blood PumpsArtificial Organs, 1996
- In vitro flow experiments for determination of optimal geometry of total cavopulmonary connection for surgical repair of children with functional single ventricleJACC, 1996
- A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connectionJournal of Biomechanics, 1996
- Flow studies on atriopulmonary and cavopulmonary connections of the Fontan operations for congenital heart defectsJournal of Biomedical Engineering, 1993
- Vascular Fluid Mechanics, the Arterial Wall, and AtherosclerosisJournal of Biomechanical Engineering, 1992
- The role of blood flow in platelet adhesion, fibrin deposition, and formation of mural thrombiMicrovascular Research, 1973