Edema and elasticity of a fronto-temporal decompressive craniectomy
Open Access
- 1 January 2012
- journal article
- research article
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 3 (1) , 11
Abstract
Background: Decompressive craniectomy is undertaken for relief of brain herniation caused by acute brain swelling. Brain stiffness can be estimated by palpating the decompressive cranial defect and can provide some relatively subjective information to the neurosurgeon to help guide care. The goal of the present study was to objectively evaluate transcutaneous stiffness of the cranial defect using a tactile resonance sensor and to describe the values in patients with a decompressive window in order to characterize the clinical association between brain edema and stiffness.Methods: Data were prospectively collected from 13 of 37 patients who underwent a decompressive craniectomy in our hospital during a 5-year period. Transcutaneous stiffness was measured as change in frequency and as elastic modulus.Results: Stiffness variables of the decompressive site were measured without any adverse effect and subsequent calculations revealed change in frequency = 101.71 ± 36.42 Hz, and shear elastic modulus = 1.99 ± 1.11 kPa.Conclusions: The elasticity of stiffness of a decompressive site correlated with brain edema, cisternal cerebrospinal fluid pressure, and brain shift, all of which are related to acute brain edema.Keywords
This publication has 12 references indexed in Scilit:
- Tactile resonance sensors in medicineJournal of Medical Engineering & Technology, 2009
- In vivo brain viscoelastic properties measured by magnetic resonance elastographyNMR in Biomedicine, 2008
- The measurement of brain tissue stiffness in-vivo2008
- Magnetic resonance elastography of the brainNeuroImage, 2008
- Current Status of Intraoperative Real-time Vibrography in NeurosurgeryUltraschall in der Medizin - European Journal of Ultrasound, 2007
- Material properties of porcine parietal cortexJournal of Biomechanics, 2006
- A New Tactile Skin Sensor for Measuring Skin Hardness in Patients with Systemic Sclerosis and Autoimmune Raynaud's PhenomenonJournal of International Medical Research, 2004
- A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in anin vitro human prostate modelMedical & Biological Engineering & Computing, 1999
- Impression technique for the assessment of oedema: comparison with a new tactile sensor that measures physical properties of tissueMedical & Biological Engineering & Computing, 1995
- A viscoelastic study of scalp, brain, and duraJournal of Biomechanics, 1970