A comparison of the intubating laryngeal mask tracheal tube with a standard tracheal tube for fibreoptic intubation
Authors:
Open Access
- 1 April 2000
- journal article
- clinical trial
- Published by Wiley in Anaesthesia
- Vol. 55 (4) , 358-361
Abstract
We conducted a prospective randomised study to compare the intubating laryngeal mask tracheal tube with a standard tube, for ease of tracheal intubation over a fibrescope. Thirty‐six patients were investigated, using a sequential analysis technique. Ease of intubation was improved when the intubating laryngeal mask tracheal tube was used compared with the standard tube (p = 0.0009). Median (interquartile range [range]) intubation times (time from the tube's tip being level with the patient's teeth to successful placement) were 1.5 (1–2.3 [1–3]) s when the intubating laryngeal mask tracheal tube was used and 5 (3–7.3 [3–13]) s when the standard tube was used (p < 0.0001).Keywords
This publication has 5 references indexed in Scilit:
- Nasotracheal tube placement over the fibreoptic laryngoscopeAnaesthesia, 1996
- Facilitation of Fiberoptic Orotracheal Intubation with a Flexible Tracheal TubeAnesthesia & Analgesia, 1994
- Fibreoptic intubationAnaesthesia, 1993
- The double triangular test: a sequential test for the two-sided alternative with early stopping under the null hypothesisSequential Analysis, 1990
- A clinical sign to predict difficult tracheal intubation; a prospective studyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1985