AGC Control Model of Virtual Power Plant Considering Communication Delay
Authors:
- 1 June 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 638-643
Abstract
Aiming at the communication delay and data packet loss in the process of virtual power plant participating in AGC frequency modulation, a virtual power plant AGC control model based on MPC algorithm is presented. Based on the improvement of the traditional MPC algorithm, the optimal weighting method was used to predict the random communication delay, and a cache was set up at the controlled end to deal with the packet loss problem in the communication process by using the multi-step advance prediction ability of MPC. At the same time, considering the energy storage diversity of virtual power plant, the energy storage unit is divided into two ways: distributed according to ACE (Area Control Error) signal and according to ARR (Area Regulation Requirement) signal, so as to give full play to the dual roles of quick power response and load increment of energy storage resources.Keywords
This publication has 5 references indexed in Scilit:
- Distributed MPC strategy with application to AGC in the presence of variable speed wind turbine2015
- Nonlinear distributed MPC strategy with application to AGC of interconnected power system2013
- On Load–Frequency Regulation With Time Delays: Design and Real-Time ImplementationIEEE Transactions on Energy Conversion, 2009
- Robust decentralised PI based LFC design for time delay power systemsEnergy Conversion and Management, 2008
- Application of Linear Matrix Inequalities for Load Frequency Control With Communication DelaysIEEE Transactions on Power Systems, 2004