Long pulse beam extraction with a prototype ion source for the KSTAR neutral beam system
Authors:
- 16 January 2008
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 79 (2) , 02C101
Abstract
Long pulse operational characteristics of the high current ion source for the KSTAR neutral beam system are described. The beam pulse length of 300s was successfully operated at a beam power of 1.6MW with a beam energy of 70keV. Beam energy, beam current, beam divergence, arc power, and several other operational parameters were measured during a pulse to analyze the long pulse properties. The increase of the cooling water temperature of the accelerator grids and plasma generator components were measured by water flow calorimetric system using thermocouples. The temperature rises of the filament electrodes of the ion source and the G1 grids (plasma grids) of the accelerator turned out to be the critical factors of the long pulse operation in the current system.Keywords
This publication has 5 references indexed in Scilit:
- Measurement of the Beam Power Transmission in the KSTAR Neutral Beam Test-Stand SystemJournal of the Korean Physical Society, 2007
- The KSTAR project: An advanced steady state superconducting tokamak experimentNuclear Fusion, 2000
- Discharge characteristics of a long pulse ion source for the Korea Superconducting Tokamak Advanced Research neutral beam systemReview of Scientific Instruments, 2000
- Long pulse neutral beam system for the Tokamak Physics ExperimentFusion Engineering and Design, 1995
- Electron backstream to the source plasma region in an ion sourceJournal of Applied Physics, 1980