Influence of Meniscectomy and Meniscus Replacement on the Stress Distribution in Human Knee Joint
Authors:
- 22 May 2008
- journal article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 36 (8) , 1335-1344
Abstract
Studying the mechanics of the knee joint has direct implications in understanding the state of human health and disease and can aid in treatment of injuries. In this work, we developed an axisymmetric model of the human knee joint using finite element method, which consisted of separate parts representing tibia, meniscus and femoral, and tibial articular cartilages. The articular cartilages were modeled as three separate layers with different material characteristics: top superficial layer, middle layer, and calcified layer. The biphasic characteristic of both meniscus and cartilage layers were included in the computational model. The developed model was employed to investigate several aspects of mechanical response of the knee joint under external loading associated with the standing posture. Specifically, we studied the role of the material characteristic of the articular cartilage and meniscus on the distribution of the shear stresses in the healthy knee joint and the knee joint after meniscectomy. We further employed the proposed computational model to study the mechanics of the knee joint with an artificial meniscus. Our calculations suggested an optimal elastic modulus of about 110 MPa for the artificial meniscus which was modeled as a linear isotropic material. The suggested optimum stiffness of the artificial meniscus corresponds to the stiffness of the physiological meniscus in the circumferential direction.Keywords
This publication has 54 references indexed in Scilit:
- Why lateral meniscectomy is more dangerous than medial meniscectomy. A finite element studyJournal of Orthopaedic Research, 2006
- Influence of a Superficial Tangential Zone Over Repairing Cartilage Defects: Implications for Tissue EngineeringBiomechanics and Modeling in Mechanobiology, 2006
- Meniscal replacement in dogs. Tissue regeneration in two different materials with similar propertiesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005
- An anatomically based patient-specific finite element model of patella articulation: towards a diagnostic toolBiomechanics and Modeling in Mechanobiology, 2005
- OPTIONS IN MENISCAL REPAIRClinics in Sports Medicine, 1999
- The interaction of the zone of calcified cartilage and subchondral bone in osteoarthritisMicroscopy Research and Technique, 1997
- Contact of Layered Elastic Spheres as a Model of Joint Contact: Effect of Tangential Load and FrictionJournal of Biomechanical Engineering, 1991
- An Analytical Model of Joint ContactJournal of Biomechanical Engineering, 1990
- Articular cartilage after meniscectomy: Rabbit knees studied with the scanning electron microscopeActa Orthopaedica, 1984
- The Biomechanical Function of the Collagen Fibril Ultrastructure of Articular CartilageJournal of Biomechanical Engineering, 1978