Real‐time rigid body motion correction and shimming using cloverleaf navigators
Authors:
- André J W Van Der KouweAKAndré J W Van Der Kouwe
- Thomas BennerTBThomas Benner
- Anders M DaleADAnders M Dale
- 6 October 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (5) , 1019-1032
Abstract
Subject motion during scanning can greatly reduce MRI image quality and is a major reason for discarding data in both clinical and research scanning. The quality of the high‐resolution structural data used for morphometric analysis is especially compromised by subject movement because high‐resolution scans are of longer duration. A method is presented that measures and corrects rigid body motion and associated first‐order shim changes in real time, using a pulse sequence with embedded cloverleaf navigators and a feedback control mechanism. The procedure requires a 12‐s preliminary mapping scan. A single‐path, 4.2‐ms cloverleaf navigator is inserted every repetition time (TR) after the readout of a 3D fast low‐angle shot (FLASH) sequence, requiring no additional RF pulses and minimally impacting scan duration. Every TR, a rigid body motion estimate is made and a correction is fed back to adjust the gradients and shim offsets. Images are corrected and reconstructed on the scanner computer for immediate access. Correction for between‐scan motion can be accomplished by using the same reference map for each scan repetition. Human and phantom tests demonstrated a consistent improvement in image quality if motion occurred during the acquisition. Magn Reson Med, 2006.Keywords
This publication has 19 references indexed in Scilit:
- Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imagingMagnetic Resonance in Medicine, 2004
- Novel interleaved spiral imaging motion correction technique using orbital navigatorsMagnetic Resonance in Medicine, 2003
- Real‐time autoshimming for echo planar timecourse imagingMagnetic Resonance in Medicine, 2002
- Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain ImagesNeuroImage, 2002
- Spherical navigator echoes for full 3D rigid body motion measurement in MRIMagnetic Resonance in Medicine, 2001
- Real-time motion correction using octant navigatorsNeuroImage, 2001
- AFNI: Software for Analysis and Visualization of Functional Magnetic Resonance NeuroimagesComputers and Biomedical Research, 1996
- Orbital navigator echoes for motion measurements in magnetic resonance imagingMagnetic Resonance in Medicine, 1995
- Fast Three Dimensional Magnetic Resonance ImagingMagnetic Resonance in Medicine, 1995
- Animating rotation with quaternion curvesACM SIGGRAPH Computer Graphics, 1985