Optochemical sensor for determining ozone based on novel soluble indigo dyes immobilised in a highly permeable polymeric film
Authors:
- 29 June 2005
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 382 (7) , 1628-1641
Abstract
An optochemical ozone sensor is described that has been manufactured by immobilisation of novel soluble indigo derivatives in permeable transparent polymeric films of polydimethylsiloxane–polycarbonate copolymer. From a number of investigated indigo derivatives, 4,4′,7,7′-tetraalkoxyindigo 9 has been selected for optimal sensitivity and specificity of ozone detection. A linear calibration for ozone can be obtained in the range between 0.01 and 0.5 ppm. The limit of quantitation is 0.03 ppm, and the accuracy exceeds 8%. It takes about 134 s to measure the relatively low occupational exposure concentration of 0.1 ppm. A reduction of the sensor response time could be achieved through application of double-sided coated sensors instead of single-sided variants. The stability of the sensors and the effect of external parameters like relative humidity (RH), temperature and gas flow on the sensor response have been investigated. The sensor response is affected by varying the gas flow or temperature; however, humidity in the range between 0 and 90% RH does not affect sensor response. The indigo derivative 9 remained stable inside the polymeric film and no chemical reaction, crystallisation or leaching occurred during 10 months of observation. Proper choice of indicator dye and polymeric material and successful application of kinetic evaluation method for the exposure experiments determine the desired features of the sensor.Keywords
This publication has 23 references indexed in Scilit:
- Methods for gas-phase measurements of ozone, ozone precursors and aerosol precursorsAtmospheric Environment, 2000
- Ozone Measurement with Passive Samplers: Validation and Use for Ozone Pollution Assessment in Montpellier, FranceEnvironmental Science & Technology, 1998
- Development and Evaluation of a Small Active Ozone SamplerEnvironmental Science & Technology, 1997
- Monitoring ambient ozone with a passive measurement technique method, field results and strategyWater, Air, & Soil Pollution, 1996
- Ambient ozone (O3) in three Class I wilderness areas in the northeastern USA: Measurements with Ogawa passive samplersEnvironmental Pollution, 1996
- Measurement of ambient ozone using a nitrite-coated filterAnalytical Chemistry, 1993
- Continuous measurement of ozone in air by chemiluminescence using ndigo-5,5′-disulphonateAnalytica Chimica Acta, 1990
- Quantitative determination of aqueous-phase ozone by chemiluminescence using indigo-5,5'-disulfonateAnalytical Chemistry, 1989
- Determination of ozone in water by the indigo methodWater Research, 1981
- A specific spectrophotometric determination of ozone in air in the presence of sulfur dioxide and nitrogen oxidesAnalytica Chimica Acta, 1979