Transition edge sensors for bolometric applications: responsivity and saturation
Authors:
- 15 April 2008
- journal article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 103 (8)
Abstract
Microstrip-coupled transition edge sensors (TESs) combined with waveguide-horn technology produce sensitive bolometric detectors with well-defined, single-mode beam patterns and excellent polarization characteristics. These devices are now being deployed for astronomical observations. In bolometric applications, where power levels are monitored, the critical parameter that characterizes the detection is the power-to-current responsivity sI(ω), where ω is the postdetection angular frequency. In real applications, such as on a ground-based telescope, the signal of interest is superimposed on a background such as the thermal emission from the atmosphere. The power emitted by the atmosphere changes slowly in time and these changes may change the responsivity of the detector. A detailed understanding of how sI(ω) changes as a function of applied power levels and how the TES response saturates is vital for accurate calibration of astronomical data. In this paper we describe measurements of the changes in the current flowing through a TES as a function of the circuit bias and the applied power. From these measurements we calculate the efficiency of the coupling of power into the TES from a closely thermally coupled microstrip termination resistor and we determine the zero frequency responsivity sI(0) as a function of both the circuit bias and power. The variation of the responsivity is compared with predictions of a small-signal model: for the case when the loop gain LI is high, when simplifying approximations to the full solution to the electrothermal equations apply; and using the electrothermal parameters of the TES, determined by impedance measurements, as inputs to the full model solution. We find good agreement between theory and measurement in both cases in the relevant regimes.Keywords
This publication has 22 references indexed in Scilit:
- APEX-SZ first light and instrument statusNew Astronomy Reviews, 2006
- Complex microcalorimeter models and their application to position-sensitive detectorsJournal of Applied Physics, 2006
- A tightly coupled dc SQUID with an intermediary transformerPhysica C: Superconductivity and its Applications, 2002
- The Optical/Infrared Astronomical Quality of High Atacama Sites. II. Infrared CharacteristicsPublications of the Astronomical Society of the Pacific, 2001
- Thermal fluctuation noise in a voltage biased superconducting transition edge thermometerApplied Physics Letters, 2000
- Thermal-response time of superconducting transition-edge microcalorimetersJournal of Applied Physics, 1998
- High‐resolution, energy‐dispersive microcalorimeter spectrometer for X‐ray microanalysisJournal of Microscopy, 1997
- Improved dc SQUID read-out electronics with low 1/f noise preamplifierReview of Scientific Instruments, 1997
- Electron-phonon scattering rates in disordered metallic films below 1 KPhysical Review B, 1992
- Bolometer noise: nonequilibrium theoryApplied Optics, 1982