Monolithic polymer layer with gradient of hydrophobicity for separation of peptides using two‐dimensional thin layer chromatography and MALDI‐TOF‐MS detection
Authors:
- Frantisek SvecFSFrantisek Svec
- 22 June 2011
- journal article
- Published by Wiley in Journal of Separation Science
- Vol. 34 (16-17) , 2345-2351
Abstract
Superhydrophobic monolithic porous polymer layers supported onto glass plates with a gradient of hydrophobicity have been prepared and used for 2-D thin layer chromatography of peptides. The 50 μm-thin poly(glycidyl methacrylate-co-ethylene dimethacrylate) layers prepared using UV-initiated polymerization in a simple mold were first hydrolyzed using dilute sulfuric acid and then hydrophilized via two-step grafting of poly(ethylene glycol) methacrylate to obtain superhydrophilic plates. The hydrophobicity was then formed by photografting of lauryl methacrylate. The exposure to UV light that initiates photografting was spatially controlled using moving shutter that enabled forming of the diagonal gradient of hydrophobicity. This new concept enables the solutes to encounter the gradient for each of the two sequential developments. Practical application of our novel plates was demonstrated with a rapid 2-D separation of a mixture of model peptides gly-tyr, val-tyr-val, leucine enkephalin, and oxytocin in dual reversed-phase mode using different mobile phases in each direction. Detection of fluorescent-labeled peptides was achieved through UV light visualization while separation of native leucine enkephalin and oxytocin was monitored directly using MALDI mass spectrometry.Keywords
This publication has 22 references indexed in Scilit:
- Separation of Peptides and Oligonucleotides Using a Monolithic Polymer Layer and Pressurized Planar Electrophoresis and ElectrochromatographyAnalytical Chemistry, 2010
- Monolithic Superhydrophobic Polymer Layer with Photopatterned Virtual Channel for the Separation of Peptides Using Two-Dimensional Thin Layer Chromatography-Desorption Electrospray Ionization Mass SpectrometryAnalytical Chemistry, 2010
- Porous Polymer Coatings: a Versatile Approach to Superhydrophobic SurfacesAdvanced Functional Materials, 2009
- Technique for Ultrathin Layer Chromatography Using an Electrospun, Nanofibrous Stationary PhaseAnalytical Chemistry, 2009
- Highly Efficient Enzyme Reactors Containing Trypsin and Endoproteinase LysC Immobilized on Porous Polymer Monolith Coupled to MS Suitable for Analysis of AntibodiesAnalytical Chemistry, 2009
- Planar ChromatographyAnalytical Chemistry, 2008
- Photopatterning Enzymes on Polymer Monoliths in Microfluidic Devices for Steady-State Kinetic Analysis and Spatially Separated Multi-Enzyme ReactionsAnalytical Chemistry, 2007
- Monolithic Porous Polymer Layer for the Separation of Peptides and Proteins Using Thin-Layer Chromatography Coupled with MALDI-TOF-MSAnalytical Chemistry, 2006
- Porous polymer monolith for surface‐enhanced laser desorption/ionization time‐of‐flight mass spectrometry of small moleculesRapid Communications in Mass Spectrometry, 2004
- Shielded Stationary Phases Based on Porous Polymer Monoliths for the Capillary Electrochromatography of Highly Basic BiomoleculesAnalytical Chemistry, 2004