Long-Term Improvements in Glycemic Control with Dexcom CGM Use in Adults with Noninsulin-Treated Type 2 Diabetes
Open Access
- 13 December 2024
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 26 (12) , 925-931
Abstract
Aims: The objective of this real-world, observational study was to evaluate change in continuing glucose monitoring (CGM) metrics for 1 year after CGM initiation in adults with noninsulin-treated type 2 diabetes (T2D). Methods: Data were analyzed from Dexcom G6 and G7 users who self-reported: T2D, ≥18 years, gender, no insulin use, and had a baseline percent time in range (TIR) 70–180 mg/dL of ≤70%. Outcomes were change in CGM metrics from baseline to 6 and 12 months overall and for younger (n = 3,840) were mean (SD) 52.5 (11.2) years, 47.9% female, mean TIR was 41.7% (21.4%), and 12.4% of participants were ≥65 years. Significant improvement in all CGM metrics not meeting target values at baseline was observed at 6 months, with continued improvement at 12 months. Mean baseline TIR increased by 17.3% (32.1%) from 41.7% (21.4%) to 59.0% (28.9%), and mean glucose management indicator decreased by 0.5% (1.2%) from 8.1% (0.9%) to 7.6% (1.1%) (both P < 0.001). Participants who maintained or customized the high alert default setting of 250 mg/dL had a greater increase in TIR and TITR compared with participants who disabled the alert. Days of CGM use over 12 months were high in 84.7% (15.9%). Conclusion: In this large, real-world study of adults with suboptimally controlled T2D not using insulin, Dexcom CGM use was associated with meaningful improvements in glycemic control over 12 months. Use of the high alert system feature was positively associated with glycemic outcomes. High use of CGM over 12 months suggests benefits related to consistent CGM use in this population.Keywords
This publication has 26 references indexed in Scilit:
- Continuous glucose monitoring for the routine care of type 2 diabetes mellitusNature Reviews Endocrinology, 2024
- Comparison of Care Quality Metrics in 2-Sided Risk Medicare Advantage vs Fee-for-Service Medicare ProgramsJAMA Network Open, 2022
- The Optimal Duration of a Run-In Period to Initiate Continuous Glucose Monitoring for a Randomized TrialDiabetes Technology & Therapeutics, 2022
- Trends in Diabetes Treatment and Control in U.S. Adults, 1999–2018The New England journal of medicine, 2021
- American Association of Clinical Endocrinology Clinical Practice Guideline: The Use of Advanced Technology in the Management of Persons With Diabetes MellitusEndocrine Practice, 2021
- Association Between Continuous Glucose Monitoring-Derived Time in Range, Other Core Metrics, and Albuminuria in Type 2 DiabetesDiabetes Technology & Therapeutics, 2020
- Time in Range Is Associated with Carotid Intima-Media Thickness in Type 2 DiabetesDiabetes Technology & Therapeutics, 2020
- Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 DiabetesDiabetes Therapy, 2017
- Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin InjectionsJAMA, 2017
- Role of continuous glucose monitoring for type 2 in diabetes management and researchJournal of Diabetes and its Complications, 2017