Abstract
A fault isolation and estimation scheme for turn-to-turn short circuit (TTSC) in the permanent magnet synchronous motor (PMSM) systems is proposed in this paper. When the short circuit fault occurs, the fault phase current will change, while to simplify the calculation difficulty, the short-circuit fault is modelled as current change in the two-phase rotating coordinate system. Then a fault detection observer is designed to detect the fault occurrence time, then the coordinate transformation technique is developed to convert the system into subsystems affected only by single fault. Adaptive observers are designed to estimate the fault and disturbance simultaneously. The observer parameters are determined by linear matrix inequality. The specific location of the short-circuit fault can be known after the inverse Park transformation. Finally, experimental results and comparison experimental results provide evidence of the feasibility of the suggested algorithm.
Funding Information
  • Excellent Youth Foundation of Henan Scientific Committee (222300420019)
  • National Natural Science Foundation of China (61973278)
  • Basic Research Projects of Key Scientific Research Projects of Colleges and Universities in Henan Province (21zx007)
  • Key Technologies Research and Development Program of Henan Province (232102221008)

This publication has 37 references indexed in Scilit: