Biologic Response to Orthopedic Sutures: A Histologic Study in a Rabbit Model
Authors:
- Leah OchoaLOLeah Ochoa
- David RankinDRDavid Rankin
- Brett D. OwensBOBrett D. Owens
- 1 November 2009
- journal article
- Published by SLACK, Inc. in Orthopedics
- Vol. 32 (11) , 828-833
Abstract
Biologic reactivity to suture materials can have an effect on patient outcomes. The goal of this study was to determine the histologic response to 8 commonly used orthopedic sutures—Ethibond (Ethicon, Somerville, New Jersey), Ticron (Tyco, Waltham, Massachusetts), HiFi (Linvatec, Largo, Florida), Ultrabraid (Smith & Nephew, Memphis, Tennessee), MaxBraid (Biomet, Warsaw, Indiana), Orthocord (Mitek, Raynham, Massachusetts), MagnumWire (Opus Medical, San Juan Capistrano, California), and FiberWire (Arthrex, Naples, Florida)—using a rabbit model. The suture granuloms were evaluated at 30, 60, and 120 days with measurement of the fibrous capsule, the number of giant cells in and near the capsule, and the overall inflammatory grade: 1 (mild), 2 (moderate), and 3 (severe). MagnumWire and Ticron sutures initiated a more intense inflammatory reaction when compared to the other sutures. By 120 days, MagnumWire ( P =.0297) and Ticron ( P =.1855) had fewer giant cells at the soft tissue–suture interface, fewer giant cells within the capsule ( P =.0074 and P =.0377, respectively), and the greatest capsular thickness of all suture types ( P <.0001 and P =.1378, respectively). Differences exist between the biologic reactivity of commonly used orthopedic sutures that may be attributable to their material composition and/or braid characteristics. In comparison to other high-strength sutures, MagnumWire and Ticron stimulated a more intense foreign body inflammatory response.Keywords
This publication has 14 references indexed in Scilit:
- Wound Complications Following the Use of FiberWire in Lower-Extremity Traumatic AmputationsJournal of Bone and Joint Surgery, 2009
- Late Foreign-Body Reaction to Ticron Sutures following Inferior Capsular ShiftThe American Journal of Sports Medicine, 2004
- Foreign‐Body Reaction to the Bioabsorbable Suretac DeviceArthroscopy, 2000
- Symptomatic Interarticular Migration of Glenoid Suture AnchorsArthroscopy, 2000
- Multinucleated giant cellsCurrent Opinion in Hematology, 2000
- An unusual foreign body in the bladder 7 years after a Stamey endoscopic bladder neck suspensionInternational Urogynecology Journal, 1998
- Paravesical suture granuloma resembling bladder carcinoma on CT scanningBritish Journal of Radiology, 1996
- Necrobiotic Palisading Suture Granulomas Simulating Rheumatoid NoduleAmerican Journal of Surgical Pathology, 1993
- Physical and Chemical Configuration of Sutures in the Development of Surgical InfectionAnnals of Surgery, 1973
- Role of Suture Materials in the Development of Wound InfectionAnnals of Surgery, 1967