Micelle‐enhanced spectrofluorimetric method for determination of sitagliptin and identification of potential alkaline degradation products using LC‐MS
- 5 April 2013
- journal article
- research article
- Published by Wiley in Luminescence
- Vol. 29 (1) , 65-73
Abstract
A novel, quick, simple and highly sensitive spectrofluorimetric method was developed and validated for the determination of sitagliptin (SG) in its pharmaceutical formulations. The proposed method is based on investigation of the fluorescence spectral behavior of sitagliptin in an SDS micellar system. In an aqueous solution of phosphate buffer pH 4.0, the fluorescence intensity of SG in the presence of SDS was greatly enhanced, by 200%, i.e. twofold enhancement. The fluorescence intensity of SG was measured at 300 nm after excitation at 270 nm. The method showed good linearity in the range 0.03–10.0 µg/mL with a good correlation coefficient (r = 0.9998). The limits of detection and quantitation values were 5.31 and 16.1 ng/mL, respectively. The proposed method was successfully applied to the analysis of SG in its single and co‐formulated commercial tablets; the results were in good agreement with those obtained using a reference method. Application of the proposed method was extended to stability studies of SG after exposure to different forced degradation conditions according to the ICH guidelines, such as acidic, alkaline, thermal, photo‐ and oxidative stress. The chemical structure of certain potential degradation products (DPs) were investigated using LC‐MS. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
This publication has 21 references indexed in Scilit:
- Cardiovascular Biology of the Incretin SystemEndocrine Reviews, 2012
- Simultaneous Determination of Sitagliptin Phosphate Monohydrate and Metformin Hydrochloride in Tablets by a Validated UPLC MethodScientia Pharmaceutica, 2012
- Highly Efficient Asymmetric Synthesis of SitagliptinJournal of the American Chemical Society, 2009
- LC–UV–PDA and LC–MS studies to characterize degradation products of glimepirideJournal of Pharmaceutical and Biomedical Analysis, 2008
- Sensitive liquid chromatography tandem mass spectrometry method for the quantification of sitagliptin, a DPP‐4 inhibitor, in human plasma using liquid–liquid extractionBiomedical Chromatography, 2007
- Sitagliptin: Profile of a novel DPP-4 inhibitor for the treatment of type 2 diabetesDrugs of Today, 2007
- Chain length compatibility effects in mixed surfactant systems for technological applicationsAdvances in Colloid and Interface Science, 1998
- Micelles in Analytical ChemistryCritical Reviews in Analytical Chemistry, 1990
- Micellar induced simultaneous enhancement of fluorescence and thermal lensingAnalytical Chemistry, 1988
- Micellar enhanced analytical fluorimetryTrAC Trends in Analytical Chemistry, 1984