Abstract
Two‐dimensional intersecting k‐space trajectories have previously been demonstrated to allow fast multispectral imaging. Repeated sampling of k‐space points leads to destructive interference of the signal coming from the off‐resonance spectral peaks; on‐resonance data reconstruction yields images of the on‐resonance peak, with some of the off‐resonance energy being spread as noise in the image. A shift of the k‐space data by a given off‐resonance frequency brings a second frequency of interest on resonance, allowing the reconstruction of a second spectral peak from the same k‐space data. Given the higher signal‐to‐noise per unit time characteristic of a 3D acquisition, we extended the concept of intersecting trajectories to three dimensions. A 3D, rosette‐like pulse sequence was designed and implemented on a clinical 1.5T scanner. An iterative density compensation function was developed to weight the 3D intersecting trajectories before Fourier transformation. Three volunteers were scanned using this sequence and separate fat and water images were reconstructed from the same imaging dataset. Magn Reson Med 59:581–589, 2008.Keywords
This publication has 26 references indexed in Scilit:
- Real-time metabolic imagingProceedings of the National Academy of Sciences, 2006
- Advantages of parallel imaging in conjunction with hyperpolarized helium—A new approach to MRI of the lungMagnetic Resonance in Medicine, 2006
- Spiral readout gradients for the reduction of motion artifacts in chemical shift imagingMagnetic Resonance in Medicine, 2004
- Resampling of data between arbitrary grids using convolution interpolationIEEE Transactions on Medical Imaging, 1999
- An accurate algorithm for nonuniform fast Fourier transforms (NUFFT's)IEEE Microwave and Guided Wave Letters, 1998
- Multishot rosette trajectories for spectrally selective MR imagingIEEE Transactions on Medical Imaging, 1997
- Constrained reconstruction applied to 2-D chemical shift imagingIEEE Transactions on Medical Imaging, 1997
- Frequency resolved single‐shot MR imaging using stochastic k‐space trajectoriesMagnetic Resonance in Medicine, 1996
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991
- A method of measuring field-gradient modulation shapes. Application to high-speed NMR spectroscopic imagingJournal of Physics E: Scientific Instruments, 1987