An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW
Open Access
- 7 April 2023
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 823
Abstract
Resonant microcantilevers have the advantages of ultra-high heating rates, analysis speed, ultra-low power consumption, temperature programming, and trace sample analysis when applied in TGA. However, the current single-channel testing system for resonant microcantilevers can only detect one sample at a time, and need two program heating tests to obtain the thermogravimetric curve of a sample. In many cases, it is desirable to obtain the thermogravimetric curve of a sample with a single-program heating test and to simultaneously detect multiple microcantilevers for testing multiple samples. To address this issue, this paper proposes a dual-channel testing method, where a microcantilever is used as a control group and another microcantilever is used as an experimental group, to obtain the thermal weight curve of the sample in a single program temperature ramp test. With the help of the LabVIEW’s convenient parallel running method, the functionality of simultaneously detecting two microcantilevers is achieved. Experimental validation showed that this dual-channel testing system can obtain the thermogravimetric curve of a sample with a single program heating test and detect two types of samples simultaneously.Keywords
Funding Information
- National Key Research and Development Program of China (2021YFB3200600, 2021YFB3200602)
This publication has 44 references indexed in Scilit:
- Thermogravimetric heat and mass transfer: Modeling of bitumen pyrolysisFuel, 2015
- The critical role of water at the gold-titania interface in catalytic CO oxidationScience, 2014
- Diffusional effects for the oxidation of SiC powders in thermogravimetric analysis experimentsJournal of Materials Science, 2013
- ICTAC Kinetics Committee recommendations for performing kinetic computations on thermal analysis dataThermochimica Acta, 2011
- Resonant-cantilever bio/chemical sensors with an integrated heater for both resonance exciting optimization and sensing repeatability enhancementJournal of Micromechanics and Microengineering, 2009
- Zeptogram-Scale Nanomechanical Mass SensingNano Letters, 2006
- Thermal Decomposition of CaC2O4·H2O Studied by Thermo-Raman Spectroscopy with TGA/DTAAnalytical Chemistry, 1997
- Concentrations of Radon-222 in Coal Mines in England and ScotlandNature, 1968
- Extraction of Meaningful Kinetic Parameters from Thermogravimetric AnalysisNature, 1968
- Thermogravimetric analysis. A reviewThe Analyst, 1963