A multiplex real-time PCR (quantitative PCR [qPCR]) assay detecting herpes simplex virus (HSV) and varicella-zoster virus (VZV) DNA together with an internal control was developed on the BD Max platform combining automated DNA extraction and an open amplification procedure. Its performance was compared to those of PCR assays routinely used in the laboratory, namely, a laboratory-developed test for HSV DNA on the LightCycler instrument and a test using a commercial master mix for VZV DNA on the ABI7500fast system. Using a pool of negative cerebrospinal fluid (CSF) samples spiked with either calibrated controls for HSV-1 and VZV or dilutions of a clinical strain that was previously quantified for HSV-2, the empirical limit of detection of the BD Max assay was 195.65, 91.80, and 414.07 copies/ml for HSV-1, HSV-2, and VZV, respectively. All the samples from HSV and VZV DNA quality control panels (Quality Control for Molecular Diagnostics [QCMD], 2013, Glasgow, United Kingdom) were correctly identified by the BD Max assay. From 180 clinical specimens of various origins, 2 CSF samples were found invalid by the BD Max assay due to the absence of detection of the internal control; a concordance of 100% was observed between the BD Max assay and the corresponding routine tests. The BD Max assay detected the PCR signal 3 to 4 cycles earlier than did the routine methods. With results available within 2 h on a wide range of specimens, this sensitive and fully automated PCR assay exhibited the qualities required for detecting simultaneously HSV and VZV DNA on a routine basis.Keywords
This publication has 50 references indexed in Scilit:
- Impact of Herpes simplex virus load and red blood cells in cerebrospinal fluid upon herpes simplex meningo-encephalitis outcomeBMC Infectious Diseases, 2012
- Comparison of the BD Max Methicillin-Resistant Staphylococcus aureus (MRSA) Assay and the BD GeneOhm MRSA Achromopeptidase Assay with Direct- and Enriched-Culture Techniques Using Clinical Specimens for Detection of MRSAJournal of Clinical Microbiology, 2012
- Multicenter Evaluation of the BD Max GBS Assay for Detection of Group B Streptococci in Prenatal Vaginal and Rectal Screening Swab Specimens from Pregnant WomenJournal of Clinical Microbiology, 2010
- Viral loads of herpes simplex virus in clinical samples—A 5‐year retrospective analysisJournal of Medical Virology, 2010
- Relative Quantity of Cerebrospinal Fluid Herpes Simplex Virus DNA in Adult Cases of Encephalitis and Meningitis: Table 1American Journal of Clinical Pathology, 2009
- Maternal and Neonatal Herpes Simplex Virus InfectionsNew England Journal of Medicine, 2009
- Monitoring of herpes simplex virus DNA types 1 and 2 viral load in cerebrospinal fluid by real‐time PCR in patients with herpes simplex encephalitisJournal of Medical Virology, 2009
- Optimizing PCR Positivity Criterion for Detection of Herpes Simplex Virus DNA on Skin and MucosaJournal of Clinical Microbiology, 2007
- Quantitative real time PCR detection of Varicella-zoster virus DNA in cerebrospinal fluid in patients with neurological diseaseMedical Microbiology and Immunology, 2004
- Herpes Simplex Viruses2002