Adherent Endotoxin on Dental Implant Surfaces: A Reappraisal
Authors:
- 1 February 2015
- journal article
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 41 (1) , 10-16
Abstract
Osteoimmunology is the crosstalk between cells from the immune and skeletal systems, suggesting a role of pro-inflammatory cytokines in the stimulation of osteoclast activity. Endotoxin or bacterial challenges to inflammatory cells are directly relevant to dental implant pathologies involving bone resorption, such as osseointegration failure and peri-implantitis. While the endotoxin amount on implant devices is regulated by standards, it is unknown whether commercially available dental implants elicit different levels of adherent-endotoxin stimulated cytokines. The objective of this work is to develop a model system and evaluate endotoxin-induced expression of pro-inflammatory cytokine genes relevant to osteoclast activation on commercially available dental implants. Murine J774-A1 macrophages were cultured on Ti disks with different level of lipopolysaccharide (LPS) contamination to define the time-course of the inflammatory response to endotoxin, as evaluated by reverse transcription polymerase chain reaction analysis. The developed protocol was then used to measure adherent endotoxin on commercially available packaged and sterile dental implants in the “as-implanted” condition. Results show that tested dental implants induce variable expression of endotoxin-stimulated genes, sometimes above the level expected to promote bone resorption in vivo. Results are unaffected by the specific surface treatment; rather, they likely reflect care in cleaning and packaging protocols. In conclusion, expression of genes that enhance osteoclast activity through endotoxin stimulation of inflammatory cells is widely different on commercially available dental implants. A reappraisal of the clinical impact of adherent endotoxins on dental (and bone) implant devices is required in light of increasing knowledge on crosstalk between cells from the immune and skeletal systems.Keywords
This publication has 32 references indexed in Scilit:
- Characterization of topographical effects on macrophage behavior in a foreign body response modelBiomaterials, 2010
- Osteoclasts and the immune systemJournal of Bone and Mineral Metabolism, 2009
- Lymphocyte adhesion and interactions with biomaterial adherent macrophages and foreign body giant cellsJournal of Biomedical Materials Research Part A, 2009
- Arachidonic Acid and Prostaglandin E2 Influence Human Osteoblast (MG63) Response to Titanium Surface RoughnessJournal of Oral Implantology, 2008
- Inflammation and Bone Loss in Periodontal DiseaseJournal of Periodontology, 2008
- Foreign body reaction to biomaterialsSeminars in Immunology, 2008
- Phenotypic non‐equivalence of murine (monocyte‐) macrophage cells in biomaterial and inflammatory modelsJournal of Biomedical Materials Research Part A, 2008
- OsteoimmunologyImmunological Reviews, 2005
- Titanium surface topography alters cell shape and modulates bone morphogenetic protein 2 expression in the J774A.1 macrophage cell lineJournal of Biomedical Materials Research Part A, 2002
- Effect of Lipopolysaccharide Contamination on the Attachment of Osteoblast-like Cells to Titanium and Titanium Alloy In VitroJournal of Oral Implantology, 2001