Radiation damage in polymer films from grazing‐incidence X‐ray scattering measurements
Authors:
- 16 February 2016
- journal article
- research article
- Published by Wiley in Journal of Polymer Science Part B: Polymer Physics
- Vol. 54 (11) , 1074-1086
Abstract
Grazing‐incidence X‐ray scattering (GIXS) is widely used to analyze the crystallinity and nanoscale structure in thin polymer films. However, ionizing radiation will generate free radicals that initiate crosslinking and/or chain scission, and structural damage will impact the ordering kinetics, thermodynamics, and crystallinity in many polymers. We report a simple methodology to screen for beam damage that is based on lithographic principles: films are exposed to patterns of X‐ray radiation, and changes in polymer structure are revealed by immersing the film in a solvent that dissolves the shortest chains. The experiments are implemented with high throughput using the standard beam line instrumentation and a typical GIXS configuration. The extent of damage (at a fixed radiation dose) depends on a range of intrinsic material properties and experimental variables, including the polymer chemistry and molecular weight, exposure environment, film thickness, and angle of incidence. The solubility switch for common polymers is detected within 10–60 s at ambient temperature, and we verified that this first indication of damage corresponds with the onset of network formation in glassy polystyrene and a loss of crystallinity in polyalkylthiophenes. Therefore, grazing‐incidence X‐ray “patterning” offers an efficient approach to determine the appropriate data acquisition times for any GIXS experiment. © 2016 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2016, 54, 1074–1086Keywords
Funding Information
- National Science Foundation (DMR‐1151468)
- National Science Foundation (CBET‐1236606)
- U.S. Department of Energy
- U.S. Department of Energy (DE‐AC02‐06CH11357)
This publication has 53 references indexed in Scilit:
- Quantitative Determination of Organic Semiconductor Microstructure from the Molecular to Device ScaleChemical Reviews, 2012
- Polystyrene negative resist for high-resolution electron beam lithographyDiscover Nano, 2011
- Effect of Photovoltaic Polymer/Fullerene Blend Composition Ratio on Microstructure Evolution during Film Solidification Investigated in Real Time by X-ray DiffractionMacromolecules, 2011
- Grazing incidence wide angle x-ray scattering at the wiggler beamline BW4 of HASYLABReview of Scientific Instruments, 2010
- Scherrer grain-size analysis adapted to grazing-incidence scattering with area detectorsJournal of Applied Crystallography, 2009
- Equilibrium Swelling of Polystyrene Networks by Linear PolystyreneMacromolecules, 2002
- Molecular rearrangements in ultra high molecular weight polyethylene after irradiation and long-term storage in airPolymer, 1999
- Extendibility of synchrotron radiation lithography to the sub-100 nm regionJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 1996
- Fabrication of 5–7 nm wide etched lines in silicon using 100 keV electron-beam lithography and polymethylmethacrylate resistApplied Physics Letters, 1993
- Radiation‐induced crystallinity changes in linear polyethylene: Influence of agingJournal of Applied Polymer Science, 1983