Exposure to Sevoflurane and Nitrous Oxide During Four Different Methods of Anesthetic Induction
Authors:
- Klaus H. HoeraufKHKlaus H. Hoerauf
- Thomas WallnerTWThomas Wallner
- Ozan AkcaOAOzan Akca
- Reza TaslimiRTReza Taslimi
- Daniel I. SesslerDSDaniel I. Sessler
- 1 April 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 88 (4) , 925-929
Abstract
The National Institute for Occupational Safety and Health-recommended exposure levels for nitrous oxide exposure are 25 ppm as a time-weighted average over the time of exposure. The exposure limit for halogenated anesthetics (without concomitant nitrous oxide exposure) is 2 ppm. Inhaled sevoflurane provides an alternative to i.v. induction of anesthesia. However, the inadvertent release of anesthetic gases into the room is likely to be greater than that with induction involving i.v. anesthetics. We therefore evaluated anesthesiologist exposure during four different induction techniques. Eighty patients were assigned to one of the induction groups to receive: 1) sevoflurane and nitrous oxide from a rebreathing bag, 2) sevoflurane and nitrous oxide from a circle circuit, 3) propofol 3 mg/kg, and 4) thiopental sodium 5 mg/kg. Anesthesia was maintained with sevoflurane and nitrous oxide via a laryngeal mask. Trace concentrations were measured directly from the breathing zone of the anesthesiologist. During induction, peak concentrations of sevoflurane and nitrous oxide with the two i.v. methods rarely exceeded 2 ppm sevoflurane and 50 ppm nitrous oxide. Concentrations during the two inhalation methods were generally <20 ppm sevoflurane and 100 ppm nitrous oxide. During maintenance, median values were near 2 ppm sevoflurane and 50 ppm nitrous oxide in all groups. Sevoflurane concentrations during inhaled induction frequently exceeded the National Institute for Occupational Safety and Health-recommended exposure ceiling of 2 ppm but mostly remained <20 ppm. Exposure during the maintenance phase of anesthesia also frequently exceeded the 2-ppm ceiling. We conclude that operating room anesthetic vapor concentrations are increased during inhaled inductions and remain increased with laryngeal mask ventilation. We compared waste gas concentrations to sevoflurane and nitrous oxide during four different induction methods. During inhaled induction with a rebreathing bag or a circle circuit system, waste gas concentrations frequently exceed National Institute for Occupational Safety and Health limits of 2 ppm sevoflurane and 50 ppm nitrous oxide. Therefore, we recommend that people at risk (e.g., women of child-bearing age) should pay great attention when using this technique.Keywords
This publication has 26 references indexed in Scilit:
- Onset Time, Recovery Duration, and Drug Cost with Four Different Methods of Inducing General AnesthesiaAnesthesia & Analgesia, 1999
- Exposure of Postoperative Nurses to Exhaled Anesthetic GasesAnesthesia & Analgesia, 1998
- Risk of spontaneous abortion in women occupationally exposed to anaesthetic gases: a meta-analysis.Occupational and Environmental Medicine, 1997
- Occupational exposure to sevoflurane, halothane and nitrous oxide during paediatric anaesthesia Waste gas exposure during paediatric anaesthesiaAnaesthesia, 1997
- Spontaneous abortions among dental assistants, factory workers, painters, and gardening workers: a follow up study.Journal of Epidemiology and Community Health, 1984
- Exposure to Anaesthetic Gases and Spontaneous Abortion: Response Bias in a Postal Questionnaire StudyInternational Journal of Epidemiology, 1982
- Occupational exposure to anaesthetics in 20 hospitalsAnaesthesia, 1980
- Survey of Infants Born in 1973 or 1975 to Swedish Women Working in Operating Rooms during Their PregnanciesAnesthesia & Analgesia, 1979
- Health problems of anaesthetists and their families in the West Midlands.BMJ, 1979
- OUTCOME OF PREGNANCY AMONG WOMEN IN ANÆSTHETIC PRACTICEThe Lancet, 1977