Biosensor for Arsenite Using Arsenite Oxidase and Multiwalled Carbon Nanotube Modified Electrodes
Authors:
- 18 September 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (20) , 7831-7837
Abstract
A biosensor for arsenite has been developed using molybdenum-containing arsenite oxidase, prepared from the chemolithoautotroph NT-26 that oxidizes arsenite to arsenate. The enzyme was galvanostatically deposited for 10 min at 10 μA onto the active surface of a multiwalled carbon nanotube modified glassy carbon electrode. The resulting biosensor enabled direct electron transfer, i.e., effecting reduction and then reoxidization of the enzyme without an artificial electron-transfer mediator. Arsenite was detected within 10 s at an applied potential of 0.3 V with linearity up to 500 ppb and a detection limit of 1 ppb. The biosensor exhibited excellent reproducibility, 2% at 95% confidence interval for 12 repeated analyses of 25 ppb arsenite. Copper, a severe interfering species commonly found in groundwater, did not interfere, and the biosensor was applicable for repeated analysis of spiked arsenite in tap water, river water, and a commercial mineral water.Keywords
This publication has 30 references indexed in Scilit:
- Anaerobic arsenite oxidation by novel denitrifying isolatesEnvironmental Microbiology, 2006
- Effect of Dissolved Humic Substances on the Photochemical Degradation Rate of 1-Aminopyrene and AtrazineInternational Journal of Molecular Sciences, 2002
- Government and Society: Helping industry master chemical dataAnalytical Chemistry, 2002
- The Structure of the Soluble Domain of an Archaeal Rieske Iron–Sulfur Protein at 1.1Å ResolutionJournal of Molecular Biology, 2002
- Crystal Structure of the 100 kDa Arsenite Oxidase from Alcaligenes faecalis in Two Crystal Forms at 1.64 Å and 2.03 ÅStructure, 2001
- Determination of traces of arsenic(III) by anodic stripping voltammetry in solutions, natural waters and biological materialAnalytica Chimica Acta, 1998
- Structure of a water soluble fragment of the ‘Rieske’ iron–sulfur protein of the bovine heart mitochondrial cytochrome bc1 complex determined by MAD phasing at 1.5 å resolutionStructure, 1996
- Analysis of arsenic(V) by cathodic stripping voltammetryAnalytica Chimica Acta, 1995
- Thermal analysisAnalytical Chemistry, 1978
- A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye bindingAnalytical Biochemistry, 1976