Changes in intraocular pressure and optic nerve sheath diameter in patients undergoing robotic-assisted laparoscopic prostatectomy in steep 45° Trendelenburg position
Authors:
- Sebastian BlechaSBSebastian Blecha
- Marion HarthMHMarion Harth
- Felix SchlachetzkiFSFelix Schlachetzki
- Florian ZemanFZFlorian Zeman
- Christiane BlechaCBChristiane Blecha
- Pierre FloraPFPierre Flora
- Maximilian BurgerMBMaximilian Burger
- Stefan DenzingerSDStefan Denzinger
- Bernhard M. GrafBGBernhard M. Graf
- Horst HelbigHHHorst Helbig
- Michael T. PawlikMPMichael T. Pawlik
Open Access
- 11 March 2017
- journal article
- research article
- Published by Springer Nature in BMC Anesthesiology
- Vol. 17 (1) , 1-8
Abstract
To evaluate changes in intraocular pressure (IOP) and intracerebral pressure (ICP) reflected by the optic nerve sheath diameter (ONSD) in patients undergoing robotic-assisted laparoscopic prostatectomy (RALP) in permanent 45° steep Trendelenburg position (STP). Fifty-one patients undergoing RALP under a standardised anaesthesia. IOP was perioperatively measured in awake patients (T0) and IOP and ONSD 20 min after induction of anaesthesia (T1), after insufflation of the abdomen in supine position (T2), after 30 min in STP (T3), when controlling Santorini’s plexus in STP (T4) and before awakening while supine (T5). We investigated the influence of respiratory and circulatory parameters as well as patient-specific and time-dependent factors on IOP and ONSD. Average IOP values (mmHg) were T0 = 19.9, T1 = 15.9, T2 = 20.1, T3 = 30.7, T4 = 33.9 and T5 = 21.8. IOP was 14.0 ± 7.47 mmHg (mean ± SD) higher at T4 than T0 (p = 0.013). Univariate mixed effects models showed peak inspiratory pressure (PIP) and mean arterial blood pressure (MAP) to be significant predictors for IOP increase. Mean ONSD values (mm) were T1 = 5.88, T2 = 6.08, T3 = 6.07, T4 = 6.04 and T5 = 5.96. The ONSD remained permanently >6.0 mm during RALP. Patients aged <63 years showed a 0.21 mm wider ONSD on average (p = 0.017) and greater variations in diameter than older patients. The combination of STP and capnoperitoneum during RALP has a pronounced influence on IOP and, to a lesser degree, on ICP. IOP is directly correlated with increasing PIP and MAP. IOP doubled and the ONSD rose to values indicating increased intracranial pressure. Differences in the ONSD were age-related, showing higher output values as well as better autoregulation and compliance in STP for patients aged <63 years. Despite several ocular changes during RALP, visual function was not significantly impaired postoperatively. Z-2014-0387-6 . Registered 8 July 2014.Keywords
This publication has 27 references indexed in Scilit:
- Perioperative visual loss and anesthetic managementCurrent Opinion in Anaesthesiology, 2013
- Randomised Controlled Trial Comparing Laparoscopic and Robot-assisted Radical ProstatectomyEuropean Urology, 2013
- Dependence of the optic nerve sheath diameter on acutely applied subarachnoidal pressure - an experimental ultrasound studyActa Ophthalmologica, 2011
- Ultrasonography of the optic nerve in neurocritically ill patientsActa Anaesthesiologica Scandinavica, 2011
- Optic nerve sonography: a new window for the non-invasive evaluation of intracranial pressure in brain injuryEmergency Medicine Journal, 2009
- The Effects of Steep Trendelenburg Positioning on Intraocular Pressure During Robotic Radical ProstatectomyAnesthesia & Analgesia, 2009
- Retropubic, Laparoscopic, and Robot-Assisted Radical Prostatectomy: A Systematic Review and Cumulative Analysis of Comparative StudiesEuropean Urology, 2009
- Optic Nerve Ultrasound for Detection of Intracranial Hypertension in Intracranial Hemorrhage PatientsJournal of Neurosurgical Anesthesiology, 2009
- Posterior Ischemic Optic Neuropathy After Minimally Invasive ProstatectomyJournal of Neuro-Ophthalmology, 2007
- Color doppler imaging of orbital vessels: Personal experience and literature reviewJournal of Clinical Ultrasound, 2003