Dose optimization in CBCT in dentistry: a survey among EADMFR members
Open Access
- 24 September 2025
- journal article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (1) , 43-51
Abstract
Objectives: The aim of this study is to provide an overview of current cone beam CT (CBCT) practices in European dental clinics. Methods: From February to May 2023, 186 European EADMFR members were invited to complete an online survey. Participants were asked: (1) to provide exposure settings for 4 diagnostic scenarios; (2) if and how they adjust for age and body type; (3) whether they follow established protocols when selecting settings; and (4) if the Dose Area Product (DAP) is registered for CBCT scans. Results: A total of 59 (32%) eligible responses were received. There was a large variation in exposure parameters among clinicians within the same diagnostic scenario. Across scenarios, only voxel size and field of view (FOV) differed significantly (P < .05), with smaller settings being chosen for endodontic diagnostics and larger parameters for full-jaw imaging for implant planning. For young patients, most respondents reduced FOV (70%), mA (67%), and exposure time (59%). For larger patients, most increased mA (54%) and kV (52%). Written protocols were more frequently employed than manufacturer-recommended settings (75% vs 50% reported “most of the time” or “always”). More frequent usage of manufacturer-recommended settings correlated with larger FOV settings (P < .05). 90% reported registering the DAP. Conclusions: CBCT exposure parameter selection lacks consistency. Only FOV and voxel size were consistently adjusted for the indication. New guidelines providing guidance on the selection of CBCT settings could reduce variation between clinicians and enhance the uniformity of the quality of care. Advances in knowledge: Lack of uniformity in CBCT parameter selection highlights the need for updated, indication-oriented, and patient-specific guidelines.Keywords
This publication has 24 references indexed in Scilit:
- Diagnostic reference levels for dental cone-beam computed tomography: current state and way forwardPhysica Medica, 2025
- Cone beam computed tomography in dentistry: Clinical recommendations and indication-specific featuresJournal of Dentistry, 2025
- Cone beam computed tomography – Frequency and exposure settings at University (Dental) hospitals in Central and Northern EuropeEuropean Journal of Radiology, 2024
- Dental cone beam CT: An updated reviewPhysica Medica, 2021
- Novel low-dose protocols using cone beam computed tomography in dental medicine: a review focusing on indications, limitations, and future possibilitiesClinical Oral Investigations, 2019
- Cone-beam CT in paediatric dentistry: DIMITRA project position statementPediatric Radiology, 2017
- Determination of size-specific exposure settings in dental cone-beam CTEuropean Radiology, 2016
- The Effect of Alteration of the Exposure Parameters of a Cone-beam Computed Tomographic Scan on the Diagnosis of Simulated Horizontal Root FracturesJournal of Endodontics, 2015
- Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomographyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2013
- The ‘Image Gently’ campaign: increasing CT radiation dose awareness through a national education and awareness programPediatric Radiology, 2008