Novel cysteic acid/reduced graphene oxide composite film modified electrode for the selective detection of trace silver ions in natural waters
- 14 August 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (20) , 5812-5822
Abstract
Novel cysteic acid/reduced graphene oxide composite film on a glassy carbon electrode has been prepared through the electrochemical oxidation of L-cysteine for silver sensing. Differential pulse anodic stripping voltammetry (DPASV) was employed for the detection of trace Ag(I) in aqueous solutions with the composite film modified electrode, which is referred to as an efficient method for the detection of trace heavy metals. We found the linear relationship between the peak current of the stripping voltammetry of Ag(I) and the concentration of Ag(I) in the range of 1.0 × 10−8 ∼ 2.0 × 10−4 M with a correlation coefficient R2 = 0.996, and the detection limit can be down to 1.0 × 10−9 M (S/N = 3). The as-developed cysteic acid/reduced graphene oxide composite film modified electrode demonstrated ultrahigh sensitivity, reproducibility and recovery for the selective detection of trace Ag(I) without any interference from other metal ions.Keywords
This publication has 49 references indexed in Scilit:
- Simple optical determination of silver ion in aqueous solutions using benzo crown-ether modified gold nanoparticlesMicrochimica Acta, 2012
- Fabrication of a new multi-walled carbon nanotube paste electrode for stripping voltammetric determination of Ag(i)The Analyst, 2012
- Electrochemical Oxidation of Cysteine at a Film Gold Modified Carbon Fiber Microelectrode Its Application in a Flow—Through Voltammetric SensorSensors, 2012
- A homogeneous redox catalytic process for the paired synthesis of l-cysteine and l-cysteic acid from l-cystineElectrochimica Acta, 2011
- High-sensitivity determination of lead and cadmium based on the Nafion-graphene composite filmAnalytica Chimica Acta, 2009
- Determination of picomolar silver concentrations by differential pulse anodic stripping voltammetry at a carbon paste electrode modified with phenylthiourea-functionalized high ordered nanoporous silica gelElectrochimica Acta, 2009
- A potentiometric and voltammetric sensor based on polypyrrole film with electrochemically induced recognition sites for detection of silver ionElectrochimica Acta, 2007
- Voltammetric Determination of Meloxicam in Pharmaceutical Formulation and Human Serum at Glassy Carbon Electrode Modified by Cysteic Acid Formed by Electrochemical Oxidation of L-cysteineSensors, 2006
- Metal ions as enzyme effectorsRussian Chemical Reviews, 1998
- Preparation of Graphitic OxideJournal of the American Chemical Society, 1958