An ICRP-based Chinese adult male voxel model and its absorbed dose for idealized photon exposures—the skeleton
Authors:
- Zhi ZengZZZhi Zeng
- Junli LiJLJunli Li
- Binquan ZhangBZBinquan Zhang
- Rui QiuRQRui Qiu
- Jizeng MaJMJizeng Ma
- 20 October 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (21) , 6675-6690
Abstract
A site-specific skeleton voxel model for a Chinese adult male was constructed in this paper upon a previous Chinese individual voxel model. The whole skeleton was divided into 19 site-specific bones and bone groups; the mass of various skeleton tissues at each bone site, e.g. red bone marrow, was specified according to Asian reference data and the distribution data from ICRP Publication 70. The resultant voxel model (called CAM) has a resolution of 1.741 mm x 1.741 mm in plane, and the total bone mass is 8397.8 g which is almost equal to the Asian reference value. Dose coefficients for the red bone marrow and bone surface in CAM were calculated, and then compared with those from Rex, CMP and ICRP 74. It shows that the dose to RBM in Rex is generally 12% lower than that to CAM in low-energy range (30-150 keV) for AP, LAT, ROT and ISO geometries. It is also found that the RBM dose from mathematical models, i.e. CMP and ICRP 74, is underestimated by -30% in AP geometry and overestimated by 30% in PA geometry for low-energy photons. Meanwhile, the bone surface dose in the low-energy range is overestimated by 150% and 75% in CMP and ICRP 74, respectively, if compared with that from CAM.Keywords
This publication has 22 references indexed in Scilit:
- Skeletal dosimetry for external exposure to photons based on µCT images of spongiosa from different bone sitesPhysics in Medicine & Biology, 2007
- Skeletal absorbed fractions for electrons in the adult male: considerations of a revised 50- m definition of the bone endosteumRadiation Protection Dosimetry, 2007
- Response functions for computing absorbed dose to skeletal tissues from photon irradiationRadiation Protection Dosimetry, 2007
- Skeletal dosimetry in the MAX06 and the FAX06 phantoms for external exposure to photons based on vertebral 3D-microCT imagesPhysics in Medicine & Biology, 2006
- MAX06 and FAX06: update of two adult human phantoms for radiation protection dosimetryPhysics in Medicine & Biology, 2006
- All about FAX: a Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetryPhysics in Medicine & Biology, 2004
- Target cells in internal dosimetry.Radiation Protection Dosimetry, 2003
- Cells at Risk for Dosimetric Modelling Relevant to Bone Tumour InductionRadiation Protection Dosimetry, 2000
- Photoelectron Enhancement of the Absorbed Dose from X Rays to Human Bone Marrow: Experimental and Theoretical StudiesBritish Journal of Radiology, 1985
- On the Calculation of the Effective Dose EquivalentRadiation Protection Dosimetry, 1982