Comparison of blood gas parameters with hematological and biochemical parameters in critically III intensive care patients connected to mechanical ventilation
Open Access
- 27 December 2023
- journal article
- research article
- Published by Hacettepe University - Medical School in Acta Medica
- Vol. 54 (4) , 339-346
Abstract
Objective: The primary aim of this study was to compare blood gas parameters with laboratory parameters in critically ill intensive care patients who were connected to mechanical ventilation. Our secondary aim was to evaluate the effects of blood gas and laboratory parameters on mortality. Materials and Method: Critical patients over the age of 18 who were admitted to intensive care unit from emergency room or clinics and monitored with mechanical ventilation between January 1, 2021, and December 30, 2021, were included in this study. Analyses were done with the R 4.3.1 (R Core Team) program. Statistical significance was defined by p < 0.05. Results: A total of 150 patients were included in this study, and 42.6% of them were male. 62% of the men and 50% of the women in this study died. We studied the trend accuracy of laboratory hemoglobin, hematocrit, sodium, potassium, glucose and blood gas hemoglobin, hematocrit, sodium, potassium, and glucose values using a modified Bland–Altman analysis. When the analyses from the first day were examined, mean bias (LOA g/dl) for hemoglobin was 0.001 (−0.15 to 0.14) and mean bias (LOA mEq/l) for potassium was −0.19 (−0.23 to −0.16). When the third day analyses were examined, mean bias (LOA g/dl) for hemoglobin was 0.29 (−0.05 to 0.63) and mean bias (LOA mEq/l) for potassium was −0.25 (−0.29 to −0.21). Conclusion: Hemoglobin and potassium, which are blood gas parameters, can be used instead of laboratory parameters in clinical decision-making in critically ill intensive care patients on mechanical ventilation.Keywords
This publication has 9 references indexed in Scilit:
- Comparison of blood gas analysis parameters, biochemical tests and hematological parameters in geriatric patients admitted to the emergency departmentJournal of Clinical Medicine of Kazakhstan, 2023
- Correlation Between Serum and Arterial Blood Gas Bicarbonate in Patients Admitted to the Intensive Care UnitCureus, 2023
- Measuring serum sodium levels using blood gas analyzer and auto analyzer in heart and lung disease patients: A cross-sectional studyAnnals of Medicine & Surgery, 2022
- Correlation between sodium, potassium, hemoglobin, hematocrit, and glucose values as measured by a laboratory autoanalyzer and a blood gas analyzerThe American Journal of Emergency Medicine, 2019
- Can the blood gas analyser results be believed? A prospective multicentre study comparing haemoglobin, sodium and potassium measurements by blood gas analysers and laboratory auto-analysersAnaesthesia and Intensive Care, 2019
- How reliable are electrolyte and metabolite results measured by a blood gas analyzer in the ED?The American Journal of Emergency Medicine, 2016
- Point-of-care testing of electrolytes and calcium using blood gas analysers: it is time we trusted the resultsEmergency Medicine Journal, 2015
- Analysis of Bias in Measurements of Potassium, Sodium and Hemoglobin by an Emergency Department-Based Blood Gas Analyzer Relative to Hospital Laboratory Autoanalyzer ResultsPLOS ONE, 2015
- Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytesInternational Journal of Emergency Medicine, 2009