In situ Sr isotope measurement of small glass samples using multiple-Faraday collector inductively coupled plasma mass spectrometry with 1012Ω resistor high gain Faraday amplifiers
- 27 October 2014
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (2) , 515-524
Abstract
An analytical protocol was developed for correcting Kr baseline-induced bias and Rb isobaric overlap factors to analyse Sr isotope ratios for small glass samples using excimer laser ablation (LA) with an Aridus II desolvating nebuliser dual-intake system and multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The combined use of a low-oxide interface setup, along with high-gain Faraday amplifiers with a 1012 Ω resistor, enabled precise determination of Sr isotope ratios from 50–100 μm diameter craters at 10 Hz laser repetition rate. Residual analytical biases of 84Sr/86Sr and 87Sr/86Sr isotope ratios, obtained from Kr baseline suppressions (Kimura et al., 2013, Journal of Analytical Atomic Spectrometry, 28, 945–957), were found to be nonlinear, but the correction method was applicable to 50–200 μm/10 Hz craters. We also found that the 85Rb/87Rb overlap correction factor changed with time with a change in the surface condition of the sampler–skimmer cones. The correction factor of 85Rb/87Rb was thus determined at least once per five unknown measurements using the Aridus solution intake line. We determined 87Sr/86Sr isotope ratios from MkAn anorthite (Sr = 305 ppm, Rb = 0.07 ppm), BHVO-2G, KL2-G, ML3B-G (Sr = 312–396 ppm, Rb = 5.8–9.2 ppm), and BCR-2G (Sr = 337 ppm, Rb = 48.5 ppm) basalt glasses using a 50–100 μm/10 Hz crater. The results agree well with their reference values, determined by thermal ionisation mass spectrometry, even with the high Rb/Sr ratio (0.14) in the BCR-2G glass. The internal/intermediate precisions were ±0.0002 (two-standard deviation: 2SD) for 100 μm craters and ±0.0005 for 50 μm craters. The new instrument settings and analytical protocol improved the precision by a factor of two compared to the previous report using LA-(sector field)-ICP-MS and enables the analysis of sample volumes that are ten times smaller than those used in previous LA-MC-ICP-MS analyses with equal precision.Keywords
This publication has 32 references indexed in Scilit:
- Primary Magmas at the Volcanic Front of the NE Japan Arc: Coeval Eruption of Crustal Low-K Tholeiitic and Mantle-derived Medium-K Calc-Alkaline Basalts at Azuma VolcanoJournal of Petrology, 2012
- Precise and accurate determination of 147Sm/144Nd and 143Nd/144Nd in monazite using laser ablation-MC-ICPMSChemical Geology, 2011
- New Insights into Andesite Genesis: the Role of Mantle-derived Calc-alkalic and Crust-derived Tholeiitic Melts in Magma Differentiation beneath Zao Volcano, NE JapanJournal of Petrology, 2008
- Problems in obtaining precise and accurate Sr isotope analysis from geological materials using laser ablation MC-ICPMSAnalytical and Bioanalytical Chemistry, 2007
- Tracing the life history of individual barramundi using laser ablation MC-ICP-MS Sr-isotopic and Sr/Ba ratios in otolithsMarine and Freshwater Research, 2005
- In situ Sr-isotope analysis of carbonates by LA-MC-ICP-MS: interference corrections, high spatial resolution and an example from otolith studiesJournal of Analytical Atomic Spectrometry, 2004
- Small-scale Sr isotope investigation of clinopyroxenes from peridotite xenoliths by laser ablation MC-ICP-MS—implications for mantle metasomatismChemical Geology, 2003
- Improvements in precision of isotopic ratio measurements using laser ablation-multiple collector-ICP-mass spectrometry: reduction of changes in measured isotopic ratiosJournal of Analytical Atomic Spectrometry, 2003
- Magma recharge, contamination and residence times revealed by in situ laser ablation isotopic analysis of feldspar in volcanic rocksEarth and Planetary Science Letters, 2001
- Ionisation in the Solar ChromosphereNature, 1920