Electro‐Optical Multiclassification Platform for Minimizing Occasional Inaccuracy in Point‐of‐Care Biomarker Detection
Authors:
- 4 February 2024
- journal article
- research article
- Published by Wiley in Advanced Materials
- Vol. 36 (15) , e2312540
Abstract
On‐site diagnostic tests that accurately identify disease biomarkers lay the foundation for self‐healthcare applications. However, these tests routinely rely on single‐mode signals and suffer from insufficient accuracy, especially for multiplexed point‐of‐care tests (POCTs) within a few minutes. Here, this work develops a dual‐mode multiclassification diagnostic platform that integrates an electrochemiluminescence sensor and a field‐effect transistor sensor in a microfluidic chip. The microfluidic channel guides the testing samples to flow across electro‐optical sensor units, which produce dual‐mode readouts by detecting infectious biomarkers of tuberculosis (TB), human rhinovirus (HRV), and group B streptococcus (GBS). Then, machine‐learning classifiers generate three‐dimensional (3D) hyperplanes to diagnose different diseases. Dual‐mode readouts derived from distinct mechanisms enhance the anti‐interference ability physically, and machine‐learning‐aided diagnosis in high‐dimensional space reduces the occasional inaccuracy mathematically. Clinical validation studies with 501 unprocessed samples indicate that the platform has an accuracy approaching 99%, higher than the 77%–93% accuracy of rapid point‐of‐care testing technologies at 100% statistical power (>150 clinical tests). Moreover, the diagnosis time is 5 min without a trade‐off of accuracy. This work solves the occasional inaccuracy issue of rapid on‐site diagnosis, endowing POCT systems with the same accuracy as laboratory tests and holding unique prospects for complicated scenes of personalized healthcare.Keywords
Funding Information
- National Natural Science Foundation of China (61890940, 22304031, 22174022, 22127806, 22174024, 22374029, 23XD1420200)
- China Postdoctoral Science Foundation (2023M730635)
- Program of Shanghai Academic Research Leader (23XD1420200)
- Science Fund for Distinguished Young Scholars of Chongqing Municipality (DP2020036)
This publication has 66 references indexed in Scilit:
- A Single‐Molecule Bioelectronic Portable Array for Early Diagnosis of Pancreatic Cancer PrecursorsAdvanced Materials, 2023
- Graphene Transistors for In Vitro Detection of Health BiomarkersAdvanced Functional Materials, 2023
- SERS and EC dual-mode detection for dopamine based on WO3-SnO2 nanoflake arraysNano Research, 2022
- A Multifunctional Photoacoustic/Fluorescence Dual‐Mode‐Imaging Gold‐Based Theranostic Nanoformulation without External Laser LimitationsAdvanced Materials, 2022
- Emerging Biosensing Technologies for the Diagnostics of Viral Infectious DiseasesAdvanced Materials, 2022
- Active‐Matrix Sensing Array Assisted with Machine‐Learning Approach for Lumbar Degenerative Disease Diagnosis and Postoperative AssessmentAdvanced Functional Materials, 2022
- Assessment of the Feasibility of Using Noninvasive Wearable Biometric Monitoring Sensors to Detect Influenza and the Common Cold Before Symptom OnsetJAMA Network Open, 2021
- An Intelligent Graphene‐Based Biosensing Device for Cytokine Storm Syndrome Biomarkers Detection in Human BiofluidsSmall, 2021
- The Era of Digital Health: A Review of Portable and Wearable Affinity BiosensorsAdvanced Functional Materials, 2019
- Properties, variants, and applications of the immunoradiometric assay methodLa Ricerca in Clinica e in Laboratorio, 1975