Point dose calculations using an analytical pencil beam kernel for IMRT plan checking
- 14 March 2001
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (4) , 1031-1038
Abstract
A method to verify the monitor units for a treatment plan is to calculate point doses, possibly at the isocentre, by using a simple calculation method. This verification is recommended to find mistakes in the treatment plan. Treatment plans for intensity modulated radiation therapy are no exception. The method should employ a simple physical model and a dose calculation algorithm, which is different from the method used for the treatment plan. Our approach uses a convolution algorithm and an analytical pencil beam kernel with eight parameters. The model is intuitive and simple. At the same time, the method is so general that it can be applied to both step-and-shoot and sliding-window techniques. The results of applications to actual treatment plans show that the calculated total isocentre doses are accurate within +/-2% of planned doses for six-field prostate plans when calculation points are in a uniform dose region. Head and neck cases show a slightly larger difference than prostate cases. When calculation points are located in a region of high dose gradient, however, the difference could be greater than 5%.Keywords
This publication has 13 references indexed in Scilit:
- A monitor unit verification calculation in intensity modulated radiotherapy as a dosimetry quality assuranceMedical Physics, 2000
- The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapyMedical Physics, 2000
- Calculation of a pencil beam kernel from measured photon beam dataPhysics in Medicine & Biology, 1999
- Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapyMedical Physics, 1998
- The effects of divergence and nonuniformity on the x-ray pencil-beam dose kernelMedical Physics, 1996
- Experimental determination of the dose kernel in high-energy x-ray beamsMedical Physics, 1996
- Attenuation in high‐energy x‐ray beamsMedical Physics, 1994
- Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimatorsMedical Physics, 1994
- Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40Medical Physics, 1994
- Extraction of pencil beam kernels by the deconvolution methodMedical Physics, 1988