Clinical Outcomes of Cable Grip Plate–Cable Grip Constructs in the Management of Femoral Intertrochanteric Fractures
- 12 August 2026
- journal article
- Published by Istanbul University in Experimed
- Vol. 16 (2) , 120-127
Abstract
Objective: This study aimed to compare functional outcomes, complication rates, and perioperative parameters of Cable Grip Plate and Grip Cable techniques for greater trochanter fixation in elderly patients undergoing partial hip replacement for intertrochanteric femur fractures.Materials and Methods: This study included 82 patients aged \> 60 years treated between January 2020 and December 2023. Greater trochanter fixation was performed using a cable grip plate (n=45) or a grip cable system (n=37). Demographics, operative time, intraoperative blood loss, early and late complications, revision rates, functional outcomes (Harris Hip Score (HHS), Parker Mobility Score (PMS), Visual Analog Scale (VAS)), and walking aid use were compared between groups.Results: Operative time and blood loss were significantly higher in the cable grip plate group (p=0.001 and p\<0.001, respectively). Nevertheless, this group demonstrated superior functional outcomes, including higher HHS (82.7 ± 4.8 vs 79.6 ± 5.5, p=0.008), improved PMS (p=0.006), lower VAS scores (p=0.032), and earlier return to activities of daily living (p=0.009). Late complications were more frequent in the Grip Cable group (p=0.030), whereas revision rates and mortality were similar.Conclusion: Despite longer operative time and increased blood loss, cable grip plate fixation was associated with better functional recovery and fewer late complications, supporting its use for greater trochanter stabilization in this population.Keywords
This publication has 20 references indexed in Scilit:
- Greater trochanter fixed with a claw plate and cable system in complex primary and revision total hip arthroplasty: long-term follow-upInternational Orthopaedics, 2022
- Cerclage wire fixation of trochanteric osteotomies in complex hip revision: our experience and comparison with cable-plate fixationHIP International, 2021
- Revision surgery due to failed internal fixation of intertrochanteric femoral fracture: current state-of-the-artBMC Musculoskeletal Disorders, 2020
- Extended trochanteric osteotomy (ETO) fixation for femoral stem revision in periprosthetic fractures: Dall–Miles plate versus cablesEuropean Journal of Orthopaedic Surgery & Traumatology, 2017
- Greater Trochanteric Reattachment Using the Third-Generation Cable Plate System in Revision Total Hip ArthroplastyThe Journal of Arthroplasty, 2017
- Prediction of early mortality following hip fracture surgery in frail elderly: The Almelo Hip Fracture Score (AHFS)Injury, 2016
- Surgical treatment of unstable intertrochanteric fractures by bipolar hip replacement or total hip replacement in elderly osteoporotic patientsJournal of Orthopaedics and Traumatology, 2006
- Reattachment of the greater trochanter using the Dall-Miles cable grip system in revision hip arthroplastyJournal of Orthopaedic Science, 2001
- Debris From Cobalt-Chrome Cable May Cause Acetabular LooseningClinical Orthopaedics and Related Research, 1992
- Re-attachment of the greater trochanter. The use of the trochanter cable-grip systemThe Journal of Bone and Joint Surgery. British volume, 1983