Abstract
The significant benefits of preemptive arc-flash protection and the online condition monitoring of electrical equipment are quite well known. Our continuing research focuses on the development of new advanced sensor technologies that are cost-effective, reliable, and efficient for the early detection of faults in order to predict impending arc-flash occurrences in medium-voltage and low-voltage switchgear and controlgear. More extensive and detailed measurements regarding significant defects that lead to an arc-flash event have been completed since the original work in Part I was completed. A more detailed analysis of the results of this additional testing is presented in this paper. It has been documented that the two major noncontact causes that lead to an arc-flash event in switchgear are insulation degradation and thermal stresses. This paper covers the detailed measurement results under both of these conditions. New sensor technologies for both the partial discharge measurement and the thermal detection are introduced and evaluated. An effective signal processing technique, which is needed for extracting the essential indication of a developing fault, is also presented. Finally, this paper outlines how a preemptive arc detection system can be connected to protection, the programmable logic controller, or the supervisory control and data acquisition.Keywords
This publication has 8 references indexed in Scilit:
- The Smart Solution for the Prediction of Slowly Developing Electrical Faults in MV Switchgear Using Partial Discharge MeasurementsIEEE Transactions on Power Delivery, 2013
- Preemptive Arc Fault Detection Techniques in Switchgear and ControlgearIEEE Transactions on Industry Applications, 2013
- The Behavior of Arcing Faults in Low-Voltage SwitchboardsIEEE Transactions on Industry Applications, 2008
- How ultrasound can detect electrical discharge non-invasively and help eliminate arc flash incidents2007
- An Investigation into Electromagnetic Radiation due to Partial Discharges in High Voltage Equipment2007
- Design of a sensor to predict arcing faults in nuclear switchgearIEEE Transactions on Nuclear Science, 2003
- Wavelet-based denoising of partial discharge signals buried in excessive noise and interferenceIEEE Transactions on Dielectrics and Electrical Insulation, 2003
- Coaxial E-Field Probe for High-Power Microwave Measurement (Short Papers)IEEE Transactions on Microwave Theory and Techniques, 1985