Serous leak, a rare complication of polytetrafluoroethylene grafts: a case report
Open Access
- 17 November 2009
- journal article
- Published by Springer Nature in Cases Journal
- Vol. 2 (1) , 195
Abstract
Perigraft seroma is a rare complication of polytetrafluoroethylene grafts especially in the lower limb. It is often difficult to treat and recurrence is common. We present a case of a young woman who sustained a persistent perigraft seroma following a polytetrafluoroethylene graft in the proximal thigh, which was implanted as an alternative to an arteriovenous fistula. The cause was not ascertained and this was eventually treated by complete removal of the graft. This case highlights an unusual complication of polytetrafluoroethylene grafts that are commonly used in vascular access surgery, which can be challenging to treat.Keywords
This publication has 4 references indexed in Scilit:
- A comparison between PTFE and denatured homologous vein grafts for haemodialysis access: a prospective randomised multicentre trialEuropean Journal of Vascular and Endovascular Surgery, 1998
- Vascular access: concepts for the 1990s.1992
- Vascular accessJournal of the American Society of Nephrology, 1992
- AN EVALUATION OF EXPANDED POLYTETRAFLUOROETHYLENE (PTFE) LOOP GRAFTS IN THE THIGH AS VASCULAR ACCESS FOR HEMODIALYSIS IN PATIENTS WITH ACCESS PROBLEMS1988