Arterial Transit Time‐Based Multidelay Combination Strategy Improves Arterial Spin Labeling Cerebral Blood Flow Measurement Accuracy in Severe Steno‐Occlusive Diseases
- 15 July 2021
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 55 (1) , 178-187
Abstract
Background: Although perfusion imaging plays a key role in the management of steno‐occlusive diseases, the clinical usefulness of arterial spin labeling (ASL) is limited by technical issues.Purpose: To examine the effect of arterial transit time (ATT) prolongation on cerebral blood flow (CBF) measurement accuracy and identify the best CBF measurement protocol for steno‐occlusive diseases.Study Type: Prospective.Population: Moyamoya (n = 10) and atherosclerotic diseases (n = 8).Field Strength/Sequence: A 3.0T/3DT1‐weighted and ASL.Assessment: Hadamard‐encoded multidelay ASL scans with/without vessel suppression (VS) and single‐delay ASL scans with long‐label duration (LD) and long postlabeling delay (PLD), referred to as long‐label long‐delay (LLLD), were acquired. CBF measurement accuracy and its ATT dependency, measured as the correlation between the relative CBF measurement difference (ASL—single‐photon emission computed tomography [SPECT]) and ATT, were compared among 1) Combo (incorporating multidelay and LLLD data based on ATT), 2) standard (LD/PLD = 1333/2333 msec), and 3) LLLD (LD/PLD = 4000/4000 msec) protocols, using whole‐brain voxel‐wise correlation with reference standard SPECT CBF. The effect of VS on CBF measurement accuracy was also assessed.Statistical Tests: Pearson's correlation coefficient, repeated‐measures analysis of variance, t‐test. P< 0.05 was considered significant.Results: Pearson's correlation coefficients between ASL and SPECT CBF measurements were as follows: Combo = 0.55 ± 0.09; standard = 0.52 ± 0.12; LLLD = 0.41 ± 0.10. CBF measurement was least accurate in LLLD and most accurate in Combo. VS significantly improved overall CBF measurement accuracy in the standard protocol and in moyamoya patients for the Combo. ATT dependency analysis revealed that, compared with Combo, the standard and LLLD protocols showed significantly lower and negative and significantly higher and positive correlations, respectively (standard = −0.12 ± 0.04, Combo = −0.04 ± 0.03, LLLD = 0.17 ± 0.03).Data Conclusion: By using ATT‐corrected CBF derived from LD/PLD = 1333/2333 msec as a base and by compensating underestimation in delayed regions using multidelay scans, the ATT‐based Combo strategy improves CBF measurement accuracy compared with single‐delay protocols in severe steno‐occlusive diseases.Evidence Level: 1Technical Efficacy: Stage 2Keywords
This publication has 37 references indexed in Scilit:
- Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imagingMagnetic Resonance in Medicine, 2011
- RAPID Automated Patient Selection for Reperfusion TherapyStroke, 2011
- Intra- and Multicenter Reproducibility of Pulsed, Continuous and Pseudo-Continuous Arterial Spin Labeling Methods for Measuring Cerebral PerfusionJournal of Cerebral Blood Flow & Metabolism, 2011
- Patient selection for revascularization procedures in adult Moyamoya disease based on dynamic perfusion computerized tomography with acetazolamide challenge (PCTA)Neurosurgical Review, 2010
- The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test–retest studyNeuroImage, 2010
- Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fieldsMagnetic Resonance in Medicine, 2008
- Cerebrovascular insufficiency as the criterion for revascularization procedures in selected patients: a correlation study of xenon contrast-enhanced CT and PWINeurosurgical Review, 2008
- Comparative Overview of Brain Perfusion Imaging TechniquesStroke, 2005
- Prediction of the Clinical Outcome of Pediatric Moyamoya Disease With Postoperative Basal/Acetazolamide Stress Brain Perfusion SPECT After Revascularization SurgeryStroke, 2005
- Quantification of regional cerebral blood flow with IMP-SPECT. Reproducibility and clinical relevance of flow values.Stroke, 1989