Primary Frequency Response of Microgrid Using Doubly Fed Induction Generator With Finite Control Set Model Predictive Control Plus Droop Control and Storage System
Open Access
- 1 January 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 189298-189312
Abstract
This paper presents a new methodology for primary frequency response (PFR) in a microgrid through the finite control set-model predictive control (FCS-MPC) plus droop control applied to the grid side converter (GSC) of a doubly fed induction generator (DFIG). In this configuration, the rotor side converter (RSC) is responsible for maintaining wind turbine operation at the maximum power point (MPP) extraction, even at the time of a disturbance, while the GSC is responsible for processing the power required to reestablish the microgrid frequency at its rated value. The power required for frequency control comes from a battery energy storage system (BESS) connected to the DC-link, and its value is selected via the FSC-MPC by continuously adjusting the droop gain value. This control configuration has considerable benefits such as continuous operation at the MPP extraction, injection of power proportional to the frequency imbalance, the capability to impose restrictions through the control and it does not use any type of communication between the storage system and the control. Through the FCS-MPC, the gain of the droop controller is selected, which maximizes the power needed to control the frequency of the microgrid. To verify the performance of the proposed control strategy, simulations are performed for an unexpected islanding of the microgrid under different wind speed scenarios. The results show that the DFIG equipped with the proposed control strategy is able to provide ancillary services such as PFR in all DFIG operating modes.Keywords
Funding Information
- University of São Paulo
- Federal University of ABC
- CAPES agency
- CNPq agency (405757/2018-2, 305618/2017-2)
- FAPESP agency (2017/04623-3, 2016/08645-9)
This publication has 55 references indexed in Scilit:
- Coordinated operation of wind turbines and flywheel storage for primary frequency control supportInternational Journal of Electrical Power & Energy Systems, 2015
- Electrical energy storage systems: A comparative life cycle cost analysisRenewable and Sustainable Energy Reviews, 2015
- Coordinated Control Strategy of Wind Turbine Generator and Energy Storage Equipment for Frequency SupportIEEE Transactions on Industry Applications, 2015
- A stand-alone wind power supply with a Li-ion battery energy storage systemRenewable and Sustainable Energy Reviews, 2014
- Adaptive deloading of stand-alone wind farm for primary frequency controlEnergy Systems, 2014
- A robust controller based frequency control approach using the wind-battery coordination strategy in a small power systemInternational Journal of Electrical Power & Energy Systems, 2014
- On deloading control strategies of wind generators for system frequency regulationInternational Transactions on Electrical Energy Systems, 2014
- Power oscillation damping using wind turbines with energy storage systemsIET Renewable Power Generation, 2013
- A review of energy storage technologies for wind power applicationsRenewable and Sustainable Energy Reviews, 2012
- Supercapacitor Energy Storage Technology and its Application in Renewable Energy Power Generation System2008