Accuracy of the Masimo SET® LNCS neo peripheral pulse oximeter in cyanotic congenital heart disease
- 16 October 2015
- journal article
- research article
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 26 (6) , 1183-1186
Abstract
Introduction: Non-invasive peripheral pulse oximeters are routinely used to measure oxyhaemoglobin saturation (SpO2) in cyanotic congenital heart disease. These probes are calibrated in healthy adult volunteers between arterial saturations of ~75 and 100%, using the gold standard of co-oximetry on arterial blood samples. There are little data to attest their accuracy in cyanotic congenital heart disease.Aims: We aimed to assess the accuracy of a commonly used probe in children with cyanotic congenital heart disease.Methods: Children with cyanotic congenital heart disease admitted to the Paediatric Intensive Care Unit with an arterial line in situ were included to our study. Prospective simultaneous recordings of SpO2, measured by the Masimo SET® LNCS Neo peripheral probe, and co-oximeter saturations (SaO2) measured by arterial blood gas analysis were recorded.Results: A total of 527 paired measurements of SpO2 and SaO2 (using an ABL800 FLEX analyser) in 25 children were obtained. The mean bias of the pulse oximeter for all SaO2 readings was +4.7±13.8%. The wide standard deviation indicates poor precision. This mean bias increased to +7.0±13.7% at SaO2 recordings 2 ® LNCS Neo pulse oximeter is poor when arterial oxyhaemoglobin saturations are below 75%. It tends to overestimate saturations in children with cyanotic congenital heart disease. This may have serious implications for clinical decisions.Keywords
This publication has 15 references indexed in Scilit:
- Reliability of pulse oximetry in hypoxic newborn pigsThe Journal of Maternal-Fetal & Neonatal Medicine, 2013
- An assessment of the accuracy of pulse oximetersAnaesthesia, 2012
- The Effect of Averaging Time on Oximetry Values in the Premature InfantPediatrics, 2010
- Pulse oximeter accuracy and precision at five different sensor locations in infants and children with cyanotic heart diseaseIndian Journal of Anaesthesia, 2010
- Pulse oximeter accuracy and precision affected by sensor location in cyanotic childrenPediatric Critical Care Medicine, 2008
- Why Bland–Altman plots should use X, not (Y+X)/2 when X is a reference methodStatistics in Medicine, 2007
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Pulse Oximetry in Children with Congenital Heart Disease: Effects of Cardiopulmonary Bypass and CyanosisJournal of Intensive Care Medicine, 2004
- Accuracy of pulse oximetry in children with cyanotic congenital heart diseaseJournal of Cardiothoracic and Vascular Anesthesia, 1993
- NONINVASIVE PULSE OXIMETRY IN CHILDREN WITH CYANOTIC CONGENITAL HEART DISEASECritical Care Medicine, 1987