Refrigerant-charged integrated solar water heater
Authors:
- 1 January 1990
- journal article
- research article
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 14 (4) , 421-432
Abstract
The performance of two R-11-charged integrated solar water heater collectors was investigated experimentally for forced and natural circulation water flows. The heat transfer from the refrigerant loop to the hot water storage tank took place through a condenser of novel design integrated within the collector frame. The effect of the condenser inclination on the system efficiency was remarkable for natural circulation water flow but had no significant effect for forced circulation flow. The difference in thermal response between the refrigerant and water loops caused buildup of stored energy in the condenser. This energy affected the buoyancy forces and generated flow pulsation that caused a harmonic-like variation of the system efficiency. This effect vanished with forced water circulation flow. The system efficiency varied between 20 and 50% depending on the solar insolation.Keywords
This publication has 3 references indexed in Scilit:
- Two-phase water heater: Model and long term performanceSolar Energy, 1987
- Analysis of Heat Transfer Factors for a Heat Pipe Absorber Array Connected to a Common ManifoldJournal of Solar Energy Engineering, 1986
- Testing of refrigerant-charged solar domestic hot water systemsSolar Energy, 1985