Hemodynamics and Prognosis after Primary Cardiac Resynchronization System Implantation Compared to “Upgrade” Procedures
Authors:
- 15 September 2008
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 31 (10) , 1265-1271
Abstract
Introduction: Left bundle brunch block (LBBB) and right ventricular stimulation (RVS) may be associated with asynchrony and heart failure. Differences between these two entities and their response to cardiac resynchronization therapy (CRT) are not well defined. Methods: Patients receiving CRT from 1999 to 2006 were analyzed for cardiac events and prognosis separated between primary implants for LBBB (n = 221) and upgrades from RVS (n = 107). A subgroup of 105 patients (LBBB = 69; RVS = 36) was studied in more detail (New York Heart Association [NYHA], quality of life, brain natriuretic peptide, peakVO2, left ventricular ejection fraction [LVEF], wedge pressure, Cardiac Index, QRS, left‐right preejection period using pulsed wave doppler, septum‐lateral wall motion delay using tissue doppler imaging) at baseline and after 1 year. Results: Age (68.4 ± 11 years vs 68.7 ± 15 years, n. s.), NYHA class (3.1 vs 3.1, n. s.), LVEF (26.4 vs 28.1, n. s.), and clinical parameters were comparable between LBBB and RVS. The latter group consisted of more patients with chronic atrial fibrillation (14% vs 37%, P = 0.03). After 1 year, NYHA class (−0.8 ± 0.8 vs −0.6 ± 0.8, n. s.), LVEF (+13.7 ± 14% vs +8.7 ± 10%, n. s.), and clinical parameters improved similarly. After a median follow‐up of 2.33 ± 1.8 years in the LBBB versus 2.43 ± 1.9 years in the RVS group, there was no difference in long‐term prognosis or cardiac events in the total cohort (5‐year event rate, 53% vs 55%, P = n. s.). Conclusion: Upgrade patients showed similar baseline parameters and response to CRT as to primary implants. No difference in events or long‐term prognosis could be observed.Keywords
This publication has 17 references indexed in Scilit:
- Upgrading to biventricular pacing/defibrillation systems in right ventricular paced congestive heart failure patients: prospective assessment of procedural parameters and response rateEP Europace, 2007
- G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciencesBehavior Research Methods, 2007
- The benefit of upgrading chronically right ventricle–paced heart failure patients to resynchronization therapy demonstrated by strain rate imagingHeart Rhythm, 2006
- Biventricular Pacemaker Upgrade in Previously Paced Heart Failure Patients—Improvements in Ventricular DyssynchronyJournal of Cardiac Failure, 2006
- The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart FailureNew England Journal of Medicine, 2005
- Short-Term Effects of Right-Left Heart Sequential Cardiac Resynchronization in Patients With Heart Failure, Chronic Atrial Fibrillation, and Atrioventricular Nodal BlockCirculation, 2004
- Effects of Resynchronization Therapy on Cardiac Function in Pacemaker Patients “Upgraded” to Biventricular DevicesJournal of Cardiovascular Electrophysiology, 2004
- Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart FailureNew England Journal of Medicine, 2004
- Comparison of acute changes in left ventricular volume, systolic and diastolic functions, and intraventricular synchronicity after biventricular and right ventricular pacing for heart failureAmerican Heart Journal, 2003
- Effects of long-term right ventricular apical pacing on left ventricular perfusion, innervation, function and histologyJACC, 1994