To Improve Total Knee Prostheses Performance Using Three-Phase Ceramic-Based Functionally Graded Biomaterials
Open Access
- 22 May 2019
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 6
Abstract
One of the common issues that occur after total knee replacement surgery is the aseptic loosening. The problem usually occurs after about 15 years from the surgery. The destructive effects of residual particles due to wear, the stress shielding effect, and micro-movements are the causative factors for this type of loosening. In this research, using the advantages of functionally graded biomaterials (FGBM), it is tried to design a prosthetic system that can reduce the above-mentioned effects. For this purpose, the materials used in the most important part of the prosthesis system, i.e., the femoral part are redesigned so that the bioactivity between the prosthesis and bone, and the stress applied to the adjacent tissues increase simultaneously. In addition, to reduce the effect of wear at contact areas, wear-resistant biocompatible ceramics such as alumina and zirconia are used. The value of stress at the bone-prosthesis interface and adjacent tissues is the most important parameters. Two types of three-phase ceramic-based FGBMs are recommended. The prosthesis with three-phase hydroxyapatite-titanium-zirconia has increased the average stress in the bone tissues around high-risk areas up to 71.8% with respect to a commonly used Cr-Co prosthesis. The result for the prosthesis with three-phase hydroxyapatite-titanium-alumina is up to 65%, respectively. At bone-prosthesis interfaces, an increase of 92% in the stress for both zirconia-based and alumina-based is seen. Briefly, the recommended FGBMs can improve the bone-prosthesis performance in all desired indices.Keywords
This publication has 28 references indexed in Scilit:
- Standardized Loads Acting in Knee ImplantsPLOS ONE, 2014
- Material tailoring of the femoral component in a total knee replacement to reduce the problem of aseptic looseningMaterials & Design (1980-2015), 2013
- Aseptic loosening of femoral components – Materials engineering and design considerationsMaterials & Design (1980-2015), 2013
- Material selection in the design of the tibia tray component of cemented artificial knee using finite element methodMaterials & Design (1980-2015), 2013
- Effects of Materials of Cementless Femoral Stem on the Functional Adaptation of BoneJournal of Bionic Engineering, 2012
- Material selection for femoral component of total knee replacement using comprehensive VIKORMaterials & Design (1980-2015), 2011
- Ti based biomaterials, the ultimate choice for orthopaedic implants – A reviewProgress in Materials Science, 2009
- Ceramic Materials in Total Joint ArthroplastySeminars in Arthroplasty: JSES, 2006
- Ceramics in Total Hip ReplacementClinical Orthopaedics and Related Research, 2005
- Fractures of Ceramic BearingsClinical Orthopaedics and Related Research, 2003