Analysis of porphyrins from serum and the benefit of inert biphenyl columns for liquid chromatography separation
Open Access
- 15 September 2026
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (9) , e0357115
Abstract
Reversed-phase liquid chromatography (LC) is a major separation technique for porphyrins. We coupled C18-based LC with mass spectrometry (MS) for the detection of protoporphyrin IX (PPIX) in the context of neurosurgery, where it is used as a fluorescence marker for tumor visualisation. Here, we demonstrate advantages of the replacement of the C18 with an inert biphenyl (iBP) column, which improved separation resolution and increased detection sensitivity in LC-MS of six porphyrins (uroporphyrin I, hepta-, hexa-, and pentacarboxyporphyrin I, coproporphyrins I and III) associated with the heme biosynthesis pathway. They are of potential interest as intermediates and side products in our research on 5-aminolevulinic acid-induced fluorescence-guided neurosurgery. Porphyrins consist of conjugated π-systems which interact with aromatic stationary phases such as BP by taking advantage of π-π stacking interactions. Carryover observed with PPIX on endcapped C18 stationary phase was reduced. This improvement was due to the reduction of non-specific adsorption on metallic surfaces from the LC instrument by using inert column hardware combined with the BP stationary phase. Passivation by chemical vapor deposition was shown to reduce non-specific adsorption in the LC system better than methods using mobile phase additives. PEEK tubing in conjunction with the iBP-column provided the best results and shortened run time. Furthermore, we present a Python-based software tool for automated data processing and analyte quantification. This work contributes to our ongoing developments of porphyrin LC-MS in blood and tissue samples from glioma patients.Keywords
Funding Information
- Deutsche Krebshilfe (70116073, 70116288)
- Deutsche Krebshilfe (70116073, 70116288)
This publication has 28 references indexed in Scilit:
- Bisphenols in daily clothes from conventional and recycled material: evaluation of dermal exposure to potentially toxic substancesEnvironmental Science and Pollution Research, 2024
- Substantial benefits of an inert biphenyl column for the analysis of steroids and their phase II metabolites in biological samplesJournal of Separation Science, 2024
- Fundamentals of Porphyrin Chemistry2022
- Rapid determination of acyclovir, its main metabolite 9‐carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum using LC–MS/MSBiomedical Chromatography, 2022
- Liquid chromatography–tandem mass spectrometry of porphyrins and porphyrinogens in biological materials: separation and identification of interfering poly(ethylene) glycol by travelling wave ion mobility spectrometry/tandem mass spectrometryBiomedical Chromatography, 2013
- Fully automated standard addition method for the quantification of 29 polar pesticide metabolites in different water bodies using LC-MS/MSAnalytical and Bioanalytical Chemistry, 2013
- Liquid chromatography and mass spectrometry of haem biosynthetic intermediates: a reviewBiomedical Chromatography, 2012
- Chemical Vapour Deposition. Precursors, Processes and Applications. Edited by Anthony C. Jones and Michael L. Hitchman.Angewandte Chemie International Edition, 2009
- Porphyrin profiles in blood, urine and faeces by HPLC/electrospray ionization tandem mass spectrometryBiomedical Chromatography, 2006
- Stainless steel electrospray probe: A dead end for phosphorylated organic compounds?Journal of Chromatography A, 2006