Preoperative 123I/99mTc-Sestamibi Subtraction SPECT and SPECT/CT in Primary Hyperparathyroidism
Authors:
- Donald R. NeumannDNDonald R. Neumann
- Nancy A. ObuchowskiNONancy A. Obuchowski
- Frank P. DiFilippoFDFrank P. DiFilippo
Open Access
- 7 November 2008
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 49 (12) , 2012-2017
Abstract
The trend toward focused surgical parathyroidectomy requires precise preoperative localization of parathyroid lesions in patients with hyperparathyroidism. The purpose of this study was to directly compare the diagnostic accuracy of 99mTc-sestamibi/123I subtraction SPECT with SPECT/CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism. Methods: A total of 61 consecutive surgical patients with primary hyperparathyroidism underwent both 123I/99mTc-sestamibi subtraction SPECT and SPECT/CT scans preoperatively, using a hybrid SPECT/CT instrument that combined a dual-detector SPECT camera with a 6-slice multidetector spiral CT scanner. Four hours after being given 123I-sodium iodide orally, each patient received 99mTc-sestamibi intravenously, followed immediately by a simultaneous, dual-isotope SPECT scan of the neck and upper chest. Then, without moving the patient, we performed a non–contrast-enhanced CT scan of the same body region. Normalization and subtraction of the 123I SPECT images from the 99mTc SPECT images were performed. The subtraction SPECT and the coregistered fused SPECT/CT studies were interpreted separately, with images scored on a 5-point scale. Surgical and histopathologic findings were used as the standard of comparison. Results: Surgery was successful in 57 patients (solitary parathyroid adenoma in 48 patients, double parathyroid adenomas in 6 patients, and 10 hyperplastic parathyroid glands in 3 patients). The sensitivities of SPECT (50/70 = 71%) and SPECT/CT (49/70 = 70%) were similar (P = 0.779). The specificity of SPECT/CT (26/27 = 96%) was significantly greater than that of SPECT (13/27 = 48%; P = 0.006). The receiver-operating-characteristic area under the curve of SPECT/CT (0.833) was significantly greater than that of SPECT (0.632; P < 0.001). Conclusion: SPECT/CT is significantly more specific than dual-isotope subtraction SPECT for the preoperative identification of parathyroid lesions in patients with primary hyperparathyroidism.Keywords
This publication has 11 references indexed in Scilit:
- Comparison of SPECT/CT, SPECT, and Planar Imaging with Single- and Dual-Phase 99mTc-Sestamibi Parathyroid ScintigraphyJournal of Nuclear Medicine, 2007
- Radionuclide imaging for hyperparathyroidism (HPT): Which is the best technetium-99m sestamibi modality?Surgery, 2006
- Endocrine Neoplasm ScintigraphyClinical Nuclear Medicine, 2006
- Technetium‐99m‐MIBI SPECT/CT in Primary HyperparathyroidismWorld Journal of Surgery, 2005
- CT-MIBI image fusion: A new preoperative localization technique for primary, recurrent, and persistent hyperparathyroidismSurgery, 2004
- Comparison Between 99mTc-Tetrofosmin/Pertechnetate Subtraction Scintigraphy and 99mTc-Tetrofosmin SPECT for Preoperative Localization of Parathyroid Adenoma in an Endemic Goiter AreaInvestigative Radiology, 2000
- Outpatient minimally invasive parathyroidectomy: A combination of sestamibi-SPECT localization, cervical block anesthesia, and intraoperative parathyroid hormone assaySurgery, 1999
- On the comparison of correlated proportions for clustered dataStatistics in Medicine, 1998
- Comparison of double-phase 99mTc-sestamibi with 123I-99mTc-sestamibi subtraction SPECT in hyperparathyroidism.American Journal of Roentgenology, 1997
- 99Tcm sestamibi — a new agent for parathyroid imagingNuclear Medicine Communications, 1989