The automated processing algorithm to correct the test result of serum neuron‐specific enolase affected by specimen hemolysis
Open Access
- 7 July 2021
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 35 (9) , e23895
Abstract
Introduction: Serum neuron‐specific enolase (NSE) is an important tumor marker for small cell lung cancer and neuroblastoma. However, the test of serum NSE compromised by specimen hemolysis is presented as a falsely higher result, which seriously disturbs clinical decision. This study aimed to establish a solution integrated with laboratory information system to clear the bias from hemolysis on serum NSE test.Methods: The reference range of serum hemolysis index (HI) was first established, and specimen hemolysis rate was compared between HI test and visual observation. NSE concentration in serum pool with normal HI was spiked with serial diluted lysates from red blood cells to deduce individual corrective equation. The agreement between individual corrective equation and original NSE test was assayed by Bland and Altman plots.Results: The high HI existed in 32.6% of specimens from patients. The NSE median of hemolyzed specimens was significant higher than the baseline (p = 0.038), while the corrected NSE median had no difference compared with the baseline (p = 0.757). The mean difference of corrected NSE and initial NSE was 1.92%, the SD of difference was 5.23%, and furthermore, the difference was independent of tendency of HI (Spearman r = −0.069, p = 0.640). The 95% confidence interval of mean difference (from −8.33% to 12.17%) was less than the acceptable bias range (±20%).Conclusion: The agreement between individual correction equation and NSE assay was satisfied. Our automated processing algorithm for serum NSE could provide efficient management of posttest data and correct positive bias from specimen hemolysis.Keywords
This publication has 33 references indexed in Scilit:
- Individualized correction of neuron-specific enolase (NSE) measurement in hemolyzed serum samplesClinica Chimica Acta, 2013
- Short-term prognostic value of serum neuron specific enolase and S100B in acute stroke patientsClinical Biochemistry, 2012
- Neuron-Specific Enolase, S100B, and Glial Fibrillary Acidic Protein Levels as Outcome Predictors in Patients With Severe Traumatic Brain InjuryNeurosurgery, 2011
- Derivation and validation of an equation for adjustment of neuron-specific enolase concentrations in hemolyzed serumPediatric Critical Care Medicine, 2009
- ProGRP: a new biomarker for small cell lung cancerClinical Biochemistry, 2004
- Quantitation of 14-3-3 and neuron-specific enolase proteins in CSF in Creutzfeldt–Jakob diseaseNeurology, 2001
- Use of 14-3-3 and other brain-specific proteins in CSF in the diagnosis of variant Creutzfeldt-Jakob diseaseJournal of Neurology, Neurosurgery & Psychiatry, 2001
- Enolase Isoenzymes as Tumour MarkersClinical Chemistry and Laboratory Medicine (CCLM), 1986
- Blood Platelets Contain a Neuron‐Specific Enolase SubunitJournal of Neurochemistry, 1980
- Neurone-specific enolase is a molecular marker for peripheral and central neuroendocrine cellsNature, 1978