Accelerometer Systolic Time Intervals as Fast-Response Sensors of Upright Posture in the Young
Authors:
- 1 October 1995
- journal article
- Published by Wolters Kluwer Health in Circulation
- Vol. 92 (7) , 1849-1859
Abstract
Background Sensors of posture may improve rate-adaptive pacing in syndromes where syncope occurs in the upright posture, particularly in the young. No sensor of posture has been described to date. Previous studies suggest that two sensors currently under investigation (preejection period [PEP] and left ventricular ejection time [LVET] systolic time intervals [STIs] and accelerometers) may be affected by posture. A PEP-sensing pacemaker is available commercially in which heart rate (HR) decreases with an increase in PEP (∂[HR]/∂[PEP]Methods and Results We studied accelerometer-derived STIs in head-upright tilt-testing with β-blockade and catecholamine stimulation in patients with syncope or presyncope using an ultra-low-frequency accelerometer placed on the chest. Thirty-two patients age 6 to 22 years with unexplained recurrent syncope or presyncope underwent tilt-testing involving two to four tilts (60°) at baseline, during esmolol infusion (500 μg/kg load, 50 to 140 μg/kg per minute), after esmolol withdrawal, and during isoproterenol infusion if not contraindicated. PEP, LVET, and other indexes were quantified, and their relations to posture and to autonomic state were determined. With tilt, PEP increased from 98.9±2.2 to 109.1±2.8 msec ( P <.0001), and LVET decreased (supine-to-upright) from 295.5±4.5 to 247.2±4.7 msec ( P <.0001). PEP/LVET changed from 0.337±0.01 to 0.45±0.02 ( P <.0001). Similar postural changes were observed during tilt with β-blockade and esmolol withdrawal, and during isoproterenol infusion. STI changes occurred immediately on postural change and were stable. Postural change of PEP was greater than the β-adrenergic effect by 6:1. Postural change of STIs was independent of vagal tone. Conclusions First, accelerometer-derived STIs detect postural changes. Because these changes are independent of autonomic tone and are rapid and stable, they may be useful as fast-response sensors of upright posture in rate-adaptive pacemakers. Second, with postural change, HR increases when PEP increases. However, PEP-sensing pacemakers presently under investigation assume the opposite (inverse) mathematical relationship. Therefore, current PEP-sensing pacemakers use an incorrect algorithm for physiological postural responses in syncope patients. These data predict a paradoxical tachycardic response to the supine posture in patients implanted with these devices.Keywords
This publication has 30 references indexed in Scilit:
- The role of pacing for the management of neurally mediated syncope: Carotid sinus syndrome and vasovagal syncopeAmerican Heart Journal, 1994
- Clinical features and management of young patients with cardioinhibitory response during orthostatic testingThe American Journal of Cardiology, 1992
- Activity‐Based Pacing: Comparison of a Device Using an Accelerometer Versus a Piezoelectric CrystalPacing and Clinical Electrophysiology, 1992
- Recurrent Symptoms after Ventricular Pacing in Unexplained SyncopePacing and Clinical Electrophysiology, 1990
- Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakersThe American Journal of Cardiology, 1989
- A New Mechanical Sensor for Detecting Body Activity and Posture, Suitable for Rate Responsive PacingPacing and Clinical Electrophysiology, 1988
- Physiological Principles of a New Method for Rate Responsive Pacing Using the Pre‐ejection IntervalPacing and Clinical Electrophysiology, 1988
- Rate Modulation by Arm Movements of the Respiratory Dependent Rate Responsive PacemakerPacing and Clinical Electrophysiology, 1988
- Exercise Testing in the Diagnosis of Sick Sinus Syndrome in the Elderly: Implications for TreatmentPacing and Clinical Electrophysiology, 1987
- A critical review of the systolic time intervals.Circulation, 1977