Intraobserver error associated with measurements of the hand
- 22 April 2005
- journal article
- research article
- Published by Wiley in American Journal of Human Biology
- Vol. 17 (3) , 368-371
Abstract
Measurements of the hand are common in studies that use anthropometric data. However, despite widespread usage, relatively few studies have formally assessed the degree of measurement error associated with standard measurements of the hand. This is significant because high amounts of measurement error can invalidate statistical results. In this paper, intraobserver precision estimates for measures of total hand length and total 3rd-digit length were evaluated from repeated measures on 90 subjects (180 separate hands and fingers). From this replicate data, three precision estimates were calculated: the technical error of measurement (TEM), the relative technical error of measurement (rTEM), and the coefficient of reliability (R). For both measurements, all three estimates yielded a very high degree of precision (TEM < 2 mm, rTEM < 1%, and R ≥ 0.95). These results suggest that both total hand length and 3rd-digit length are sufficiently precise for anthropometric research applications. Am. J. Hum. Biol. 17:368–371, 2005.Keywords
This publication has 10 references indexed in Scilit:
- Sexual orientation and the 2nd to 4th finger length ratio: evidence for organising effects of sex hormones or developmental instability?Psychoneuroendocrinology, 2003
- Are body fluctuating asymmetry and the ratio of 2nd to 4th digit length reliable predictors of semen quality?Human Reproduction, 2003
- Relative Lengths of Fingers and Toes in Human Males and FemalesHormones and Behavior, 2002
- Anthropometric measurement error and the assessment of nutritional statusBritish Journal of Nutrition, 1999
- The ratio of 2nd to 4th digit length: a predictor of sperm numbers and concentrations of testosterone, luteinizing hormone and oestrogenHuman Reproduction, 1998
- Facial measurements in clinical genetics: How important are the instruments we use?American Journal of Medical Genetics, 1998
- Fluctuating asymmetry and psychometric intelligenceProceedings Of The Royal Society B-Biological Sciences, 1997
- A New, Old Method for Assessing Measurement Error in Both Univariate and Multivariate Morphometric StudiesSystematic Zoology, 1990
- MEASUREMENT ERROR AND ITS IMPACT ON PARTIAL CORRELATION AND MULTIPLE LINEAR REGRESSION ANALYSES1American Journal of Epidemiology, 1988
- Anthropometry of U.S. Infants and ChildrenSAE International Journal of Advances and Current Practices in Mobility, 1975