Three-dimensional stress analysis of threaded cups – a finite element analysis
Authors:
Open Access
- 21 February 2007
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 32 (2) , 195-201
Abstract
A three-dimensional model of the left acetabulum with inserted threaded cup has been generated, based on the finite element method, to calculate stress patterns in the standing phase during walking. In this study, a hemispherical cup with sharp threads, a parabolic cup with flat threads and a conical cup with sharp threads were analysed and compared. Stress patterns in both implant components and adjacent bony structures were calculated in a directly postoperative situation. The different cups were found to induce different stress patterns, deformations and shifting tendencies. The inlays deform notably and show characteristic rotational movement patterns together with the shell. The inclination angle increases in the hemispherical cup and decreases in the parabolic cup. The conical cup levers outward almost parallel to the bone stock by approximately 0.05 mm. The pole surfaces of the various cups – especially the very convex area next to the threads – induce increased compressive stress in the superior section of the acetabular base. This is increased by a factor of three in the conical cup in comparison to the hemispherical cup and less so in comparison to the parabolic cup. This study illustrates that three-dimensional stress calculations are suitable for procuring additional biomechanical information to augment clinical studies, for evaluating implants and for establishing stability prognoses, especially for newly developed prototypes.Keywords
This publication has 15 references indexed in Scilit:
- Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 yearsArchives of orthopaedic and trauma surgery, 2006
- Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stemThe Journal of Bone and Joint Surgery. British volume, 2005
- Ten to Twelve-Year Results With the Zweymüller Cementless Total Hip ProsthesisThe Journal of Arthroplasty, 2005
- Factors influencing the revision rate of Zweymueller acetabular cupInternational Orthopaedics, 2004
- A 10-year minimum follow-up of hydroxyapatite-coated threaded cupsThe Journal of Arthroplasty, 2003
- Gewindedesign von SchraubpfannenZeitschrift für Orthopädie und ihre Grenzgebiete, 2001
- Computer simulations of stress-related bone remodeling around noncemented acetabular componentsThe Journal of Arthroplasty, 1993
- Finite element analysis of acetabular reconstruction: Noncemented threaded cupsActa Orthopaedica, 1987
- Fracture of long bones: Rate effects under singular and combined loading statesJournal of Biomechanics, 1982
- An axisymmetric model of acetabular components in total hip arthroplastyJournal of Biomechanics, 1982