Use of power-line interference for adaptive motion artifact removal in biopotential measurements
Authors:
- 7 December 2015
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 37 (1) , 25-40
Abstract
Motion artifacts (MA) have long been a problem in biopotential measurements. Adaptive filtering is widely used for optimal noise removal in many biomedical applications. However, the existing adaptive filtering methods involve the use of additional sensors, limiting the applicability of adaptive filtering for MA reduction. In the present study, a novel adaptive filtering method without need for additional sensors is proposed. In biopotential measurements, movement of the electrodes and their leads may cause variations not only in the skin and half-cell potential (motion artifacts), but also in the electrode-skin impedance. Such impedance variations may also cause power-line interference modulation (PLIM), resulting in additional spectral components around the power-line interference (PLI) in the frequency domain. Demodulation of the PLI may reflect the movement-induced electrode-skin impedance variation, and can therefore represent a reference signal for the adaptive filter. Preliminary validation on ECG measurements with seven volunteers showed a high correlation coefficient ( R = 0.97) between MA and PLIM, and excellent MA removal by the proposed adaptive filter, possibly leading to improved analysis of biopotential signals.Keywords
Funding Information
- Stichting voor de Technische Wetenschappen
- China Scholarship Council
This publication has 24 references indexed in Scilit:
- The Effects of a 28-Hz Vibration on Arm Muscle Activity during Isometric ExerciseMedicine & Science in Sports & Exercise, 2009
- Continuous Monitoring of Electrode--Skin Impedance Mismatch During Bioelectric RecordingsIEEE Transactions on Biomedical Engineering, 2008
- An Improved Adaptive Power Line Interference Canceller for ElectrocardiographyIEEE Transactions on Biomedical Engineering, 2006
- New insights into the noise reduction Wiener filterIEEE Transactions on Audio, Speech, and Language Processing, 2006
- Motion Artifact Cancellation in NIR Spectroscopy Using Wiener FilteringIEEE Transactions on Biomedical Engineering, 2005
- Investigation into the origin of the noise of surface electrodesMedical & Biological Engineering & Computing, 2002
- Physician interpretation of electrocardiographic artifact that mimics ventricular tachycardiaThe American Journal of Medicine, 2001
- A multistage representation of the Wiener filter based on orthogonal projectionsIEEE Transactions on Information Theory, 1998
- The origin of skin-stretch-caused motion artifacts under electrodesPhysiological Measurement, 1996
- 60-Hz Interference in ElectrocardiographyIEEE Transactions on Biomedical Engineering, 1973