Simple methods to reduce patient dose in a Varian cone beam CT system for delivery verification in pelvic radiotherapy
Authors:
- T KronT Kron
- F ForoudiFFF Foroudi
- A HaworthAHA Haworth
- C FoxCFC Fox
- A MullenAMA Mullen
- J CrambJCJ Cramb
- 1 October 2009
- journal article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 82 (982) , 855-859
Abstract
Cone-beam computed tomography (CBCT) is a three-dimensional imaging modality that has recently become available on linear accelerators for radiotherapy patient position verification. It was the aim of the present study to implement simple strategies for reduction of the dose delivered in a commercial CBCT system. The dose delivered in a CBCT procedure (Varian, half-fan acquisition, 650 projections, 125 kVp) was assessed using a cylindrical Perspex phantom (diameter, 32 cm) with a calibrated Farmer type ionisation chamber. A copper filter (thickness, 0.15 mm) was introduced increasing the half value layer of the beam from 5.5 mm Al to 8 mm Al. Image quality and noise were assessed using an image quality phantom (CatPhan) while the exposure settings per projection were varied from 25 ms/80 mA to 2 ms/2 mA per projection. Using the copper filter reduced the dose to the phantom from approximately 45 mGy to 30 mGy at standard settings (centre/periphery weighting 1/3 to 2/3). Multiple CBCT images were acquired for six patients with pelvic malignancies to compare CBCTs with and without a copper filter. Although the reconstructed image is somewhat noisier with the filter, it features similar contrast in the centre of the patient and was often preferred by the radiation oncologist because of greater image uniformity. The X-ray shutters were adjusted to the minimum size required to obtain the desired image volume for a given patient diameter. The simple methods described here reduce the effective dose to patients undergoing daily CBCT and are easy to implement, and initial evidence suggests that they do not affect the ability to identify soft tissue for the purpose of treatment verification.Keywords
This publication has 16 references indexed in Scilit:
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Determination of the weighted CT dose index in modern multi-detector CT scannersPhysics in Medicine & Biology, 2007
- Imaging doses from the Elekta Synergy X-ray cone beam CT systemBritish Journal of Radiology, 2007
- Dose comparison of megavoltage cone‐beam and orthogonal‐pair portal imagesJournal of Applied Clinical Medical Physics, 2007
- Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapyPhysics in Medicine & Biology, 2007
- Evaluation of on-board kV cone beam CT (CBCT)-based dose calculationPhysics in Medicine & Biology, 2007
- Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform)Cancer/Radiothérapie, 2006
- Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapyBritish Journal of Radiology, 2006
- Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapyPhysics in Medicine & Biology, 2006
- Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005