Conventional deadbeat predictive current control (DPCC) of dual three-phase permanent magnet synchronous machines (DTP-PMSMs) heavily relies on precise motor parameters. Its performance is significantly limited under complex conditions, such as parameter mismatch and nonlinear inverter effects. To enhance the robustness and harmonic suppression performance of DTP-PMSMs, this article proposes an improved DPCC scheme utilizing a moving horizon estimator (MHE). The observation model based on the MHE principle estimates the interference caused by the electromotive force and parameter mismatch, while eliminating the influence of rotor flux changes in the algorithm. A time-domain horizon is constructed using historical information, and a quadratic cost function is designed to estimate and compensate for disturbances. This control strategy is applied to the main and harmonic subspaces, enhancing the robustness and suppressing the effects of the fifth- and seventh-harmonic currents. Finally, the proposed method's robustness and harmonic suppression effectiveness are validated through experimental analysis of the DTP-PMSM system.