Effect of Particle Size on the Performance of an N95 Filtering Facepiece Respirator and a Surgical Mask at Various Breathing Conditions
- 20 August 2013
- journal article
- research article
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 47 (11) , 1180-1187
Abstract
The effect of aerosol particle size on the performance of an N95 filtering facepiece respirator (FFR) and a surgical mask (SM) was evaluated under different breathing conditions, including breathing frequency and mean inspiratory flow (MIF) rate. The FFR and SM were sealed on a manikin headform and challenged with charge-equilibrated NaCl aerosol. Filter penetration (P filter) was determined as the ratio of aerosol concentrations inside and outside the FFR/SM size-selectively (28 channels) within a range of 20 to 500 nm. In addition, the same models of the FFR and SM were donned, but not sealed, on an advanced manikin headform covered with skin-like material. Total inward leakage (TIL), which represents the total particle penetration, was measured under conditions identical to the filter penetration experiment. Testing was conducted at four mean MIFs (15, 30, 55, and 85 L/min) combined with five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). The results show that SM produced much higher P filter and TIL values, and thus provide little protection against aerosols in the size range tested. P filter was significantly affected by particle size and breathing flow rate (p < 0.05) for the tested FFR and SM. Surprisingly, for both devices, P filter as a function of the particle size exhibited more than one peak under all tested breathing conditions. The effect of breathing frequency on P filter was generally less pronounced, especially for lower MIFs. For the FFR and SM, TIL increased with increasing particle size up to about 50 nm; for particles above 50 nm, the total penetration was not significantly affected by particle size and breathing frequency; however, the effect of MIF remained significant. Copyright 2013 American Association for Aerosol ResearchKeywords
This publication has 23 references indexed in Scilit:
- Development of an Advanced Respirator Fit-Test HeadformJournal of Occupational and Environmental Hygiene, 2013
- Instruments Based on Electrical Detection of Aerosols2011
- Effect of Particle Size on Respiratory Protection Provided by Two Types of N95 Respirators Used in Agricultural SettingsJournal of Occupational and Environmental Hygiene, 2010
- Performance of an N95 Filtering Facepiece Particulate Respirator and a Surgical Mask During Human Breathing: Two Pathways for Particle PenetrationJournal of Occupational and Environmental Hygiene, 2009
- Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic FlowAnnals of Occupational Hygiene, 2009
- Filter Performance of N99 and N95 Facepiece Respirators Against Viruses and Ultrafine ParticlesAnnals of Occupational Hygiene, 2008
- Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks?American Journal of Infection Control, 2006
- Manikin-Based Performance Evaluation of N95 Filtering-Facepiece Respirators Challenged with NanoparticlesAnnals of Occupational Hygiene, 2005
- Effect of Exposure to Diesel Exhaust Particles on the Susceptibility of the Lung to InfectionEnvironmental Health Perspectives, 2001
- CHARACTERISTICS OF FACE SEAL LEAKAGE IN FILTERING FACEPIECESAIHA Journal, 1992