Quantum Noise in a Fabry-Perot Interferometer Including the Influence of Diffraction Loss of Light
Authors:
- Shoki IwaguchiSIShoki Iwaguchi
- Tomohiro IshikawaTITomohiro Ishikawa
- Masaki AndoMAMasaki Ando
- Yuta MichimuraYMYuta Michimura
- Kentaro KomoriKKKentaro Komori
- Koji NaganoKNKoji Nagano
- Tomotada AkutsuTATomotada Akutsu
- Mitsuru MushaMMMitsuru Musha
- Rika YamadaRYRika Yamada
- Izumi WatanabeIWIzumi Watanabe
- Takeo NaitoTNTakeo Naito
- Taigen MorimotoTMTaigen Morimoto
Open Access
Abstract
The DECi-hertz Interferometer Gravitational wave Observatory (DECIGO) is designed to detect gravitational waves at frequencies between 0.1 and 10 Hz. In this frequency band, one of the most important science targets is the detection of primordial gravitational waves. DECIGO plans to use a space interferometer with optical cavities to increase its sensitivity. For evaluating its sensitivity, diffraction of the laser light has to be adequately considered. There are two kinds of diffraction loss: leakage loss outside the mirror and higher-order mode loss. These effects are treated differently inside and outside of the Fabry-Perot (FP) cavity. We estimated them under the conditions that the FP cavity has a relatively high finesse and the higher-order modes do not resonate. As a result, we found that the effects can be represented as a reduction of the effective finesse of the cavity with regard to quantum noise. This result is useful for optimization of the design of DECIGO. This method is also applicable to any FP cavities with a relatively small beam cut and the finesse sufficiently higher than 1.Keywords
All Related Versions
Funding Information
- Japan Society for the Promotion of Science (JP19H01924)
This publication has 9 references indexed in Scilit:
- Improvement of the Target Sensitivity in DECIGO by Optimizing Its Parameters for Quantum Noise Including the Effect of Diffraction LossGalaxies, 2021
- Planck2018 resultsAstronomy & Astrophysics, 2020
- Planck 2018 resultsAstronomy & Astrophysics, 2020
- Optimization of quantum noise by completing the square of multiple interferometer outputs in quantum locking for gravitational wave detectorsPhysics Letters A, 2020
- Implications of the-mode polarization measurement for direct detection of inflationary gravitational wavesPhysical Review D, 2014
- Conversion of conventional gravitational-wave interferometers into quantum nondemolition interferometers by modifying their input and/or output opticsPhysical Review D, 2001
- Possibility of Direct Measurement of the Acceleration of the Universe Using 0.1 Hz Band Laser Interferometer Gravitational Wave Antenna in SpacePhysical Review Letters, 2001
- Transmission of a Gaussian beam through a Fabry–Perot interferometerApplied Optics, 1994
- Laser Beams and ResonatorsApplied Optics, 1966