Relation of blood pressure and organ damage
- 1 June 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 36 (6) , 1276-1283
Abstract
The present cross-sectional study investigated whether central SBP and pulse pressure (PP) measured noninvasively with a novel cuff-based stand-alone monitor are more strongly associated with hypertensive end-organ damage than corresponding brachial measures. We investigated the cross-sectional association of central versus brachial SBP and PP with echocardiographic left ventricular mass index (LVMI), LV hypertrophy (LVH), carotid intima–media thickness (IMT), and increased IMT (IMT ≥ 75th percentile) among 246 participants drawn from the general population (mean age 57.2 years, 55.3% women). All blood pressure (BP) measures were positively correlated with LVMI and IMT (P < 0.001 for all). Brachial and central SBP correlated equally strongly with LVMI (r = 0.42 versus 0.40, P for difference 0.19) and IMT (r = 0.32 versus 0.33, P = 0.60). However, brachial PP correlated more strongly than central PP with LVMI (r = 0.34 versus 0.27, P = 0.03) and IMT (r = 0.40 versus 0.35, P = 0.04). In multivariable-adjusted logistic models, all four BP measures were significantly associated with LVH and increased IMT (P ≤ 0.03 for all). However, the diagnostic accuracy of logistic regression models that included brachial or central hemodynamic parameters was similar for LVH [area under curve (AUC) for SBP: 0.74 versus 0.76, P = 0.16; AUC for PP: 0.75 versus 0.73, P = 0.35] and IMT (AUC for SBP: 0.61 versus 0.61, P = 0.67; AUC for PP: 0.63 versus 0.61, P = 0.29). Our findings suggest that central SBP and PP measured with a stand-alone noninvasive BP monitor do not improve diagnostic accuracy for end-organ damage over corresponding brachial measures.Keywords
This publication has 50 references indexed in Scilit:
- Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: A systematic review and meta-analysisInternational Journal of Cardiology, 2013
- Validation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood PressureHypertension, 2011
- Invasive validation of a new oscillometric device (Arteriograph) for measuring augmentation index, central blood pressure and aortic pulse wave velocityJournal Of Hypertension, 2010
- Differences in the Magnitude of Wave Reflection Account for Differential Effects of Amlodipine- Versus Atenolol-Based Regimens on Central Blood PressureHypertension, 2009
- Role of Pulse Pressure Amplification in Arterial HypertensionHypertension, 2009
- Pulse Pressure in Youth and Carotid Intima-Media Thickness in AdulthoodStroke, 2009
- Central Pressure More Strongly Relates to Vascular Disease and Outcome Than Does Brachial PressureHypertension, 2007
- Cardiac hypertrophy in hypertension: relation to 24-h blood pressure profile and arterial stiffnessInternational Journal of Cardiology, 2004
- Effect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform characteristicsClinical Science, 2004
- Comparison of Tests of the Equality of Dependent Correlation CoefficientsJournal of the American Statistical Association, 1971